Sale!

GE FANUC IC695CPU315 | GE Fanuc PACSystems RX3i PLC Core Central Processing Card

Original price was: 999,00 ر.س.Current price is: 888,00 ر.س.

  • Model‌: GE FANUC IC695CPU315
  • ‌Brand‌: GE Fanuc (now part of Emerson Automation)
  • ‌Series‌: PACSystems RX3i High-Performance PLC CPU Line
  • ‌Core Function‌: Flagship high-performance central processing unit for GE Fanuc PACSystems RX3i PLC platforms, acting as the core industrial control logic hub, executing complex industrial control logic, 32K I/O operations per second, dual Ethernet redundant communication and up to 128K-point I/O management tasks to ensure stable and efficient operation of large industrial automation systems.
  • ‌Category‌: PACSystems RX3i High-Performance PLC CPU Module
  • ‌Key Specs‌: 1GHz Intel Celeron M 32-bit processor, 20MB RAM + 20MB Flash total 40MB memory, 128K maximum logic I/O points, dual 10/100Mbps auto-sensing Ethernet ports, hot-swap support, USA origin
  • ‌Condition‌: New Original (New Surplus)

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Product Introduction

When your GE Fanuc PACSystems RX3i PLC system needs a highly reliable high-performance CPU unit to execute complex industrial control logic, support high-speed redundant Ethernet communication and manage large-scale I/O points, this module acts as the core control brain.
It is a flagship industrial-grade high-performance CPU module from GE Fanuc PACSystems RX3i series, specially designed for large industrial automation scenarios. It is equipped with a 1GHz Intel Celeron M 32-bit processor, capable of performing up to 32K I/O operations per second, with 20MB battery-backed RAM and 20MB non-volatile Flash memory, which can accommodate complex industrial control programs and massive process data. It integrates two independent 10/100Mbps auto-sensing RJ-45 Ethernet ports, supporting Device Level Ring (DLR) network redundancy, natively supporting Modbus TCP, SRTP, EtherNet/IP and other mainstream industrial protocols, and can seamlessly connect with HMI, SCADA and other upper systems. It supports up to 128K logic I/O points, with built-in overcurrent, overheat and short-circuit protection mechanisms, and its industrial-grade design fully adapts to harsh industrial site environments, making it a core replacement part for GE Fanuc PACSystems RX3i PLC system maintenance and retrofit projects.

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

IC695CPU315

Key Technical Specifications

Parameter Value
Part Number IC695CPU315
Product Type PACSystems RX3i High-Performance PLC CPU Module
Manufacturer GE Fanuc (Emerson Automation)
Country of Origin USA
Processor Intel Celeron M 32-bit processor
Processor Clock Speed 1 GHz
Maximum I/O Operations Per Second 32K
User RAM Memory 20 MB (battery-backed for power-failure data retention)
Non-Volatile Flash Memory 20 MB
Maximum Logic I/O Points 128K points
Maximum Physical I/O Points 1024 points (limited by backplane)
Communication Interfaces 2×10/100Mbps auto-sensing RJ-45 Ethernet ports, 1×RS-232/RS-485 serial port
Supported Protocols Modbus TCP, SRTP, EtherNet/IP, Modbus RTU
Hot-Swap Support Yes, supports runtime hot-swap without system shutdown
Installation Method Standard PACSystems RX3i PLC single-slot mounting
Net Weight ~0.55 kg
Compatible Systems GE Fanuc PACSystems RX3i series PLC industrial control systems
Warranty 12 months from delivery

 

Field Application & Technical Pitfalls

Critical Industrial Scenarios

  • **Large Automotive Assembly Production Line PLC Control System: Acts as the core control CPU for GE Fanuc PACSystems RX3i PLC systems in automotive manufacturing plants, realizing stable execution of complex assembly line logic and high-speed data interaction with upper MES systems, ensuring the continuous and stable operation of automated production lines.
  • **Large Petrochemical Plant Process Control System: Delivers reliable high-performance control performance for petrochemical production line automation systems, adapting to long-term high-load operation scenarios, meeting the stable control requirements of large-scale petrochemical process equipment.
  • **Large Municipal Water Treatment Plant Distributed Control System: Adapts to humid and dusty water treatment workshop environments, providing stable high-speed logic processing support for medium and large water treatment distributed control systems.

Non-Negotiable Technical Pitfalls

  • ‌⚠️ Bold Warning 1‌: Never arbitrarily connect the Ethernet port to a non-industrial network with severe broadcast storm. The third communication channel will experience network congestion that causes the CPU to execute logic with significant delay.
  • ‌⚠️ Bold Warning 2‌: Skipping the pre-commissioning full DLR redundant network switching test will leave you with hidden communication interruption risks. This module must confirm the dual Ethernet redundant switching performance fully meets GE Fanuc PACSystems RX3i PLC control specifications before putting into operation.
  • ‌⚠️ Bold Warning 3‌: Do not arbitrarily use non-matching non-PACSystems RX3i standard backplane slots for installation. The third system bus will experience signal deviation that causes the I/O data refresh to be abnormal.

A large automotive manufacturing plant maintenance team once swapped a GE FANUC IC695CPU315 module and skipped the redundant network test. The hidden single Ethernet port failure caused the HMI data to be interrupted, resulting in a 1-hour partial shutdown of the assembly production line.

 

Quality Control (QC) SOP & Transparency

  1. ‌Inbound Verification‌: Cross-check the OEM serial number against GE Fanuc’s official PACSystems RX3i part registry, confirm the part number IC695CPU315 matches the factory label, and inspect no bent pins or corrosion on all backplane and Ethernet connectors.
  2. ‌Live Rig Testing‌: Power the unit in a calibrated GE Fanuc PACSystems RX3i PLC system test bench, simulate full-load logic operation and dual Ethernet communication scenarios, and confirm full 2-hour continuous stable operation.
  3. ‌Parameter Testing‌: Verify the 1GHz processor logic execution speed meets factory specifications, confirm the dual 10/100Mbps Ethernet communication stability meets industrial control standards, and validate all status LED indicators and battery-backed data retention functions work properly.
  4. ‌Final QA & Packaging‌: Seal the tested module in a static-shielding anti-static bag, attach a unique QC passed serial label, and nest it in foam padding inside a rigid industrial shipping carton.

 

Frequently Asked Questions (FAQ)

  • ‌Can I hot-swap this module while the PACSystems RX3i PLC system is running?‌ Yes, it supports PACSystems RX3i backplane hot-swap function, but you must first confirm that the redundant CPU channel is operating normally and has completed full program synchronization, then perform the replacement operation, otherwise you will trigger unexpected system logic out-of-control risks.
  • ‌What exact systems is this module compatible with?‌ It works natively with GE Fanuc PACSystems RX3i series PLC industrial control systems, and cannot be directly used in non-PACSystems RX3i PLC systems without custom adaptation.
  • ‌How long is the standard warranty for this new surplus unit?‌ 12 months from delivery. It covers all manufacturing defects, but does not extend to units damaged by miswiring, network broadcast storm impact, or improper program download in the field.
  • ‌How do I tell a genuine OEM unit apart from a refurbished clone?‌ Genuine GE FANUC IC695CPU315 modules have a laser-etched part number on the PCB, not a printed sticker. Clone units almost always fail the full 40MB memory continuous operation stability test.
  • ‌What is the typical lead time for shipment?‌ In-stock units ship within 48 hours. If you require official GE Fanuc factory CPU performance test documentation, add 2 extra business days to the turnaround window.
  • ‌Can this module replace the older GE Fanuc legacy PACSystems RX3i CPU unit?‌ Well, technically it fits the same standard PACSystems RX3i PLC chassis slot footprint, but you must confirm the PLC system programming software version fully supports the module before replacement to ensure 100% system compatibility.
zyq xuanchuance