Sale!

ABB SYN5201a-Z V217 3BHB006714R0217 SYNCHROTACT 5 Synchronizing Unit

Original price was: 4.555,00 ر.س.Current price is: 3.000,00 ر.س.

Brand: ABB
Model: SYN5201A-Z,V217
Part Number: 3BHB006714R0217
Type: Automatic Single-Channel Synchronizing Unit
Series: SYNCHROTACT 5
Core Function: Synchronizes a generator with a live busbar or power grid before circuit-breaker closing
Application: Generator synchronization, power generation, and electrical grid paralleling
Measuring Inputs: U1 and U2
Nominal Measuring Voltage: 50–130 V AC
Auxiliary Supply: 24–250 V DC or 100–230 V AC
Frequency: 16⅔, 50, or 60 Hz
Condition: New / New Surplus / Refurbished, subject to stock
Availability: Contact for current inventory
Warranty: 12 months

The ABB SYN5201A-Z,V217 3BHB006714R0217 is an automatic single-channel synchronizing unit from the SYNCHROTACT 5 family. It measures the voltage, frequency, and phase relationship between two electrical sources, then issues a controlled closing command when the configured synchronization conditions are satisfied.

This unit is intended for generator-to-grid or generator-to-busbar synchronization. It should not be confused with a general-purpose PLC controller, Ethernet communication module, or time-synchronization device. The actual function is electrical synchronization and controlled paralleling.

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

ABB SYN5201a-Z V217 3BHB006714R0217

ABB SYN5201a-Z V217 3BHB006714R0217

Key Technical Specifications

Parameter Specification
Product Model SYN5201A-Z,V217
ABB Part Number 3BHB006714R0217
Product Type Automatic single-channel synchronizing unit
Product Family SYNCHROTACT 5
Measuring Inputs U1 and U2
Nominal Measuring Voltage 50–130 V AC
Permissible Measuring Voltage 0 to 1.3 × Un
Nominal Frequency 16⅔, 50, or 60 Hz
Frequency Measuring Range 10–100 Hz
Phase-Angle Matching Range -179° to +180°
Slip Range 0–50%
Slip Acceleration Range 0–10%
Adjustable Paralleling Time 0–1 second
Auxiliary DC Supply 24–250 V DC
Auxiliary AC Supply 100–230 V AC
Operating Temperature +5 to +70°C
Synchronizing Channel 1
Application Generator and grid synchronization
Related Product Family SYNCHROTACT 5
Approximate Shipping Weight Verify against the actual packed unit
Warranty 12 months

ABB product data identifies the SYN 5201A-Z,V217 as an automatic synchronizing unit with two voltage-measuring inputs, a 50–130 V AC nominal measuring range, selectable 16⅔/50/60 Hz operation, and auxiliary supply options covering 24–250 V DC and 100–230 V AC.

 

Product Introduction — Anti-Template

The ABB SYN5201A-Z,V217 is designed to control the final synchronization step before a generator circuit breaker closes onto a live busbar or grid. It evaluates voltage magnitude, frequency difference, slip, and phase angle between the two measured sources. When the configured conditions are met, the unit generates the synchronizing command while accounting for the required breaker closing time.

As a single-channel SYNCHROTACT 5 device, it provides the measurement, voltage-matching, frequency-matching, synchronization-check, and paralleling-command functions required for automatic generator synchronization. The V217 version must be matched to the existing system documentation and wiring because the auxiliary supply, measuring inputs, and control outputs are part of the complete synchronization design.

ABB SYN5201a-Z V217 3BHB006714R0217

ABB SYN5201a-Z V217 3BHB006714R0217

ABB SYN5201a-Z V217 3BHB006714R0217

ABB SYN5201a-Z V217 3BHB006714R0217

QC, Procurement & Logistics SOP

1) Inbound Verification

Verify the following details on arrival:

  • Complete model: SYN5201A-Z,V217.
  • ABB part number: 3BHB006714R0217.
  • Product label and hardware revision.
  • Front-panel display, keys, and indicators.
  • Terminal blocks and connector condition.
  • Mounting hardware and enclosure condition.
  • Signs of corrosion, impact, overheating, or previous repair.
  • Correct voltage and frequency configuration.
  • Presence of manuals or parameter records when available.

The suffix V217 should be recorded exactly. Similar SYNCHROTACT models can have different configurations, channels, or application functions.

2) Functional Testing

A suitable test procedure should verify:

  1. Auxiliary power acceptance.
  2. Correct startup and self-diagnostics.
  3. Voltage measurement on U1 and U2.
  4. Frequency measurement.
  5. Phase-angle calculation.
  6. Slip and slip-acceleration monitoring.
  7. Voltage-matching output.
  8. Frequency-matching output.
  9. Synchronizing-check function.
  10. Circuit-breaker closing command.
  11. Paralleling-time compensation.
  12. Alarm and event indications.

Testing should use an approved synchronizing simulator or a controlled test bench. Do not connect an unverified unit directly to a live generator busbar.

3) QA & ESD Packaging

  • Handle the unit in an ESD-controlled area.
  • Protect the front panel and terminal blocks.
  • Use anti-static packaging where electronic boards are exposed.
  • Prevent terminal screws from loosening during transport.
  • Add shock-absorbing material around the enclosure.
  • Use moisture protection for international shipment.
  • Photograph the model label and terminal arrangement before dispatch.

4) Export & Logistics

Prepare:

  • Commercial invoice.
  • Packing list.
  • Complete model and part number.
  • Country of origin.
  • Net and gross weight.
  • Package dimensions.
  • Product description: “Automatic generator synchronizing unit.”
  • Correct customs classification.
  • End-use information if requested.

For urgent power-generation maintenance, express air shipment is normally suitable for a single unit. Larger quantities or cabinet assemblies may require reinforced packaging and consolidated freight.

ABB SYN5201a-Z V217 3BHB006714R0217

ABB SYN5201a-Z V217 3BHB006714R0217

Technical Pitfalls & Integration Warnings

1) Do not confuse synchronization with communication

The SYN5201A-Z, is an electrical synchronizing unit. It measures two AC sources and controls synchronization-related functions. Descriptions involving Ethernet, PROFINET, Modbus TCP, or precision network time synchronization should not be used unless confirmed for the exact device.

2) Confirm the measuring-voltage arrangement

The unit uses measuring inputs U1 and U2 with a nominal range of 50–130 V AC. The voltage-transformer ratio and secondary wiring must match the configured application. An incorrect transformer ratio can produce an incorrect phase or voltage comparison.

3) Check the frequency setting

The documented nominal frequency options include 16⅔, 50, and 60 Hz. The selected frequency must match the generator and busbar application. A wrong frequency configuration can prevent synchronization or generate incorrect matching commands.

4) Breaker closing time must be configured correctly

The synchronizer issues the closing command before the ideal phase coincidence point to compensate for circuit-breaker operating time. If the actual breaker closing time differs significantly from the configured value, the generator may close with excessive phase error.

5) Verify voltage and frequency matching outputs

The voltage matcher and frequency matcher may issue raise/lower commands to the generator AVR and governor. Confirm the command polarity, pulse duration, minimum pulse time, and receiving equipment before commissioning.

6) Do not bypass the synchronization check

The synchronizing-check function is intended to prevent unsafe out-of-phase closing. Never bypass it during normal operation. Testing should be performed with the generator isolated or under an approved commissioning procedure.

7) Check the exact replacement version

The SYNCHROTACT family includes single-channel and dual-channel configurations, as well as different application variants. The 3BHB006714R0217 part number should be compared with the existing label, wiring diagram, and parameter set before replacement.

 

Frequently Asked Questions

Q1. What is ABB SYN5201A-Z, 3BHB006714R0217?
It is an automatic single-channel synchronizing unit from ABB’s SYNCHROTACT 5 family. It synchronizes a generator with a live busbar or power grid before breaker closing.

Q2. What does the SYN5201A-Z, measure?
It measures the voltage and frequency relationship between two AC sources, including phase angle and slip. These values are used to determine whether the sources are suitable for paralleling.

Q3. What is the measuring-voltage range?
The nominal measuring-voltage range for U1 and U2 is 50–130 V AC, with a permissible range of 0 to 1.3 times the nominal voltage.

Q4. What auxiliary power supply does it require?
The documented supply options are 24–250 V DC or 100–230 V AC. Confirm the actual supply configuration from the device label and application wiring.

Q5. Is the , a single-channel or dual-channel device?
It is a single-channel synchronizing unit. Dual-channel versions belong to different SYNCHROTACT product designations.

Q6. Can it be used for generator-to-grid synchronization?
Yes. Its intended application includes automatic synchronization and paralleling between generators and electrical grids or busbars.

Q7. What information should I provide when ordering a replacement?
Provide the complete marking , 3BHB006714R0217, the generator or switchgear model, measuring-transformer voltage, system frequency, auxiliary supply, quantity, and destination country. This information helps confirm the correct version before quotation.

اكتشف 【SYN5201a-Z 3BHB006714R0217】 الآن، الخيار الأمثل بجودة عالية وسعر مناسب. يتميز بأداء موثوق وتصميم عملي، مع شحن سريع ودفع آمن وخدمة عملاء موثوقة. تواصل معنا الآن للحصول على عرض سعر مفصل، وسنرد عليك خلال ساعة واحدة.

 

Pre: ABB REC670 1MRK002814-AB | Bay Controller, IEC 61850, New Original

Next: ABB SYN5202A | Direct Replacement Busbar Synchronizing Controller

zyq xuanchuance