Sale!

GE UR8FH | UR Series 8-Channel Analog Input Card, New

Original price was: 666,00 ر.س.Current price is: 350,00 ر.س.

  • Model: UR8FH
  • Brand: GE / Multilin (Schneider Electric)
  • Series: UR (Universal Relay) Series — I/O expansion modules
  • Core Function: Eight-channel analog input module that adds process signal measurement to a GE Multilin UR relay
  • Category: Analog Input Module / UR I/O Expansion Card
  • Key Specs: 8 analog input channels | UR backplane interface | Field wiring via terminal blocks | Verify input ranges on unit label
  • Condition: New Original (New Surplus) / Refurbished

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

3. Key Technical Specifications

Confirm each line against the OEM datasheet and the label on your existing module before ordering. The UR8FH was built for the UR chassis, and the input ranges and firmware support must match your relay.

Parameter Value
Model UR8FH
Brand GE Multilin
Product Family UR (Universal Relay) Series
Module Type Analog input expansion module
Input Channels 8 (verify channel count on your unit label)
Input Signal Types Verify — current and voltage input options depend on the build
Input Ranges Verify with OEM datasheet — confirm on the module label
Resolution Verify with OEM datasheet
Accuracy Verify — confirm at 25 °C against the OEM datasheet
Isolation Verify — channel-to-channel and channel-to-chassis
Scan / Update Rate Verify — depends on the relay firmware and configuration
Backplane Interface UR chassis backplane — verify slot assignment and relay model
Terminal Blocks Field wiring lands on the module terminal blocks — verify terminal type
Compatible Relays UR-series relays — verify model and firmware revision
Operating Temperature –40 °C to +60 °C (typical for UR hardware — verify)
Storage Temperature –40 °C to +85 °C
Humidity 5% – 95% RH, non-condensing
Weight Verify with OEM datasheet
Certifications UL 508, CSA C22.2, CE, IEC 60255 — verify on the unit label

 

4. Product Introduction

The GE UR8FH is an eight-channel analog input module for the GE Multilin UR (Universal Relay) series. It plugs into a UR relay chassis and adds analog measurement channels for process transmitters, transducers, and other field signals that the relay’s onboard inputs cannot accommodate.

The engineering value is the channel density and the backplane integration. The relay reads the UR8FH channels as part of its own measurement set, so the analog data is available to the protection, metering, and recording functions without an external PLC or transducer box. Each channel is wired to the module terminal blocks, and the relay configuration maps the channel to the required function. Verify the input range and the terminal assignment against your relay configuration before installation.

 

5. Application Scenarios & Field Experience

Part 1 – Narrative Paragraph

The problem this module solves is input starvation on a UR relay. A relay installed for feeder protection may have enough current and voltage inputs for the protection functions but no spare channels for the process transmitters the plant wants to monitor. Adding an external PLC means a new panel, a new network drop, and a second set of engineering. The UR8FH adds eight analog channels inside the existing relay chassis. The relay firmware sees them as additional analog inputs, and the existing SCADA or station HMI can read them through the relay’s communication ports.

Part 2 – Numbered List (Application Scenarios)

  1. Power Generation – Generator Monitoring – The module adds analog inputs for bearing temperature transmitters, cooling water pressure, and lube oil pressure on a generator. The UR relay uses the data for alarm and trending alongside its protection functions.
  2. Oil & Gas – Compressor Station Monitoring – Used on a UR relay protecting a compressor feeder. The UR8FH reads discharge pressure and suction temperature transmitters, and the relay reports the values to the station SCADA over its communication port.
  3. Water Treatment – Pump Station Instrumentation – The module adds flow and level transmitter inputs to a UR relay in a pump station. The relay uses the analog values for process alarms and logs them with its event recorder.
  4. Industrial Plants – Feeder Process Monitoring – Used on a plant feeder relay where the process group wants to monitor motor winding temperature and vibration transmitter outputs. The keeps the signals inside the protection relay instead of adding a separate monitoring panel.

Part 3 – Short Field Story

A municipal utility had a UR feeder relay with no spare analog inputs. The plant wanted to add a flow transmitter and a pressure transmitter for a new pump control scheme. The integrator quoted a separate PLC and a new panel. We supplied a module. The utility’s technician installed the module in the relay chassis, landed the two transmitter signals on the terminal blocks, and mapped the channels in the relay configuration. The relay reported both values to the station HMI the same day. The PLC panel was avoided.

 

6. Standard Operating Procedure (SOP) for Quality Control

  • Visual & Origin Inspection – We verify the GE Multilin marking, the model string, and the date code. We inspect the backplane connector and the terminal blocks for bent pins or cracked plastic. A module with a damaged connector or evidence of moisture ingress is rejected.
  • Live Rig Testing – The module is inserted into a UR test chassis with a known-good relay. We verify the relay recognizes the module and that the module initializes without a configuration fault.
  • Input Channel Verification – We inject calibrated signals into each of the eight channels and verify the relay reports the correct value. We test at low, mid, and high points of the configured range.
  • Firmware Verification – We read and record the module firmware revision and confirm it is compatible with the relay firmware version. A module with an incompatible revision is set aside rather than shipped.
  • Terminal and Isolation Check – We verify the terminal block connections and apply the rated isolation voltage between channels and chassis. Leakage current must stay below the datasheet limit.
  • Configuration Backup – Where the module carries an existing configuration, we document the channel mapping and the input ranges before shipping.
  • ESD-Safe Packaging – The module is wrapped in anti-static film, seated in a conductive foam insert with the connectors protected, and packed in a double-wall carton with static warning labels.

 

7. Frequently Asked Questions (FAQ)

Q1: Will the work in my UR relay without a firmware change?

A: Only if the relay firmware revision supports the module and the input range you need. The is a UR-series module, but the relay must recognize the module type and the configuration tool must include it in the device library. Check the relay firmware revision against the OEM compatibility list before you order. If you send us the relay model and firmware revision, we can confirm the match.

Q2: What input ranges does the support?

A: I cannot confirm the exact input ranges from the model number alone. The build determines whether the channels accept current, voltage, or both, and the range is marked on the unit label. Read the label on your existing module and compare it to the replacement before you order. A mismatched input range will produce incorrect readings or no reading at all.

Q3: What is the warranty on this module?

A: We offer a 12-month warranty from the ship date. It covers input channel failure, backplane connector failure, and terminal block failure under normal operating conditions. It does not cover damage from incorrect field wiring, applied overvoltage, or ESD damage from handling without a wrist strap. We test every module in a live UR chassis before it ships.

Q4: Do you have this in stock?

A: UR-series inventory moves and varies by revision. Confirm availability before you plan an outage. If we are out of the variant you need, we will tell you what we actually have rather than quote a date we cannot hold.

Q5: Any installation pitfalls I should watch for?

A: Four. First, power down the relay chassis before inserting or removing the module unless the OEM procedure explicitly permits hot-swap for your relay model. Second, verify the input range and the terminal assignment on the replacement match the module you are removing. Third, check the field wiring for a short or a ground fault before you install the replacement; a field fault will damage the input channel. Fourth, after the swap, inject a known signal into each channel and verify the relay reports the correct value before you return the protection scheme to service. A module that powers up is not necessarily measuring correctly.