Sale!

TOSHIBA USIO21 | TC-net I/O Network Interface

Original price was: 6.500,00 ر.س.Current price is: 5.000,00 ر.س.

  • Model: USIO21
  • Brand: Toshiba
  • Series: TMEIC Unified Controller nv Series
  • Core Function: Optical-electric conversion within the TC-net I/O communication architecture.
  • Category: Industrial Communication Interface / Optical-Electric Converter
  • Key Specs: Used in the nv Series controller’s TC-net I/O network; supports the connection between optical and electrical communication segments in distributed I/O and drive configurations. Exact port configuration and electrical ratings require model-specific verification.
  • Availability & Condition: Contact us to confirm stock, condition, hardware revision, and nameplate details.

The TMEIC nv Series Controller documentation identifies the USIO21 as an optical-electric converter in the TC-net I/O architecture. It should not be confused with a conventional analog/digital I/O module or a generic Ethernet switch.

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Key Technical Specifications

Parameter Specification
Manufacturer Toshiba
Model USIO21
Product Type Optical-Electric Converter
Associated Control Platform TMEIC Unified Controller nv Series
Communication Architecture TC-net I/O
Primary Function Interface between optical and electrical communication segments
Application Distributed I/O and drive communication
Optical Network Context TC-net I/O optical fault-tolerant ring
Maximum Optical Line Distance Up to 2 km per line in the documented nv Series architecture; verify the applicable system configuration
Electrical Network Context TC-net I/O electrical fault-tolerant ring
Electrical Line Distance Up to 10 m per line in the documented nv Series architecture; verify the applicable system configuration
Power Supply Confirm from the unit nameplate and applicable manual
Optical Connector Type Confirm from the actual hardware and installation documentation
Electrical Port Configuration Confirm from the actual hardware and installation documentation
Installation Requirements Follow the applicable nv Series system layout and wiring instructions

Specification note: The network distances above refer to the documented TC-net I/O architecture, not a guarantee that every USIO21 installation supports those distances. Publicly accessible documentation does not establish all unit-level electrical and port specifications.

 

Product Introduction (Anti-Template)

When a distributed control system connects equipment across separate electrical rooms and field locations, the communication interface must match the network architecture. The TOSHIBA USIO21 is identified in TMEIC’s nv Series documentation as an optical-electric converter used within the TC-net I/O network. It supports communication between optical and electrical network segments in systems that connect controllers, distributed I/O, and drive equipment.

The USIO21 is a system-specific communication component rather than a general-purpose I/O card. Its correct application depends on the installed controller architecture, network topology, associated interface equipment, and cable arrangement. Before purchasing a replacement, verify the nameplate, connector layout, existing network configuration, and applicable system documentation.

USIO21

USIO21

USIO21

USIO21

USIO21

USIO21

QC, Procurement & Logistics SOP

  1. Inbound Verification
    Check the Toshiba nameplate and confirm the USIO21 model designation. Inspect the enclosure, optical interfaces, electrical connectors, and mounting points for physical damage. Compare the connector arrangement with the unit being replaced.
  2. Live Rig Testing
    Where compatible TMEIC equipment and approved test procedures are available, verify power-up behavior, communication status, and optical/electrical link operation. Confirm that the unit communicates correctly within the intended network configuration. A visual inspection alone does not establish full functionality.
  3. QA & Anti-Static Packaging
    Use suitable ESD precautions when handling electronic components. Protect optical interfaces from dust and scratches, keep connectors covered, and use cushioning to prevent damage during transportation.
  4. Global Logistics & Export Compliance
    Confirm the destination, shipping method, required documentation, and applicable customs classification before dispatch. Pack the unit securely for international air or sea freight and provide tracking details after shipment.

 

Technical Pitfalls & Integration Warnings

1. Network Architecture Mismatch

The USIO21 is associated with the TC-net I/O architecture used in TMEIC nv Series systems. Do not assume that it can replace a standard Ethernet switch, a serial communication module, or another optical converter simply because the connectors appear similar. Verify the system diagram and exact equipment role first.

2. Firmware and System Revision Compatibility

The available public documentation does not establish a universal firmware compatibility matrix for every revision. If the replacement has different hardware markings or a different associated software revision, check the applicable system documentation before installation. Do not assume compatibility based solely on the model designation.

3. Optical and Electrical Connection Errors

Verify the optical connector type, fiber arrangement, electrical interface, and network topology before connecting the replacement. Incorrect fiber routing or connection to the wrong network segment may prevent communication between the controller and remote equipment. Also confirm that the installed cable type and length comply with the system design.

4. ESD and Optical Interface Damage

Electrostatic discharge can damage electronic components without visible evidence. Handle the unit using appropriate ESD precautions. Optical connectors also require careful handling: keep dust caps fitted when disconnected and avoid touching or contaminating the optical end faces.

 

Frequently Asked Questions (FAQ)

Q1: What is the TOSHIBA used for?

The is identified in TMEIC nv Series documentation as an optical-electric converter used in the TC-net I/O communication architecture. It supports connections between optical and electrical network segments.

Q2: Is the a digital I/O module?

It should not be treated as a conventional digital I/O module. The documented role is optical-electric conversion within the TC-net I/O network. Verify the product identification and installed system configuration before ordering.

Q3: Which control systems use the ?

Available TMEIC documentation places it within the Unified Controller nv Series TC-net I/O architecture. Confirm the installed controller and network configuration before selecting a replacement.

Q4: Can the be replaced while the system is running?

Do not assume online replacement is supported. Disconnecting a network interface may interrupt communication with remote I/O or drive equipment. Follow the approved maintenance procedure and confirm the impact on the running process before removing the unit.

Q5: What information should I provide when requesting a quotation?

Provide the exact model number, a clear nameplate photo, hardware revision, required quantity, destination country, and photos of the existing connections if available. These details help verify the correct interface version.

Q6: What is the international delivery lead time?

Lead time depends on confirmed stock, unit condition, inspection requirements, and destination. Contact us to confirm availability and the estimated dispatch date before placing an order.

Q7: Can you arrange international shipping and export documentation?

Shipping options and available documents can be confirmed according to the destination and order requirements. Provide the delivery country, quantity, and preferred shipping method when requesting a quotation.