Sale!

Bently Nevada 330104-00-05-10-02-00 | Vibration Sensor

Original price was: 950,00 ر.س.Current price is: 650,00 ر.س.

  • Model: 330104-00-05-10-02-00
  • Brand: Bently Nevada (Baker Hughes)
  • Series: 3300 XL 8 mm Proximity Transducer System
  • Core Function: Measures shaft displacement and vibration through non-contact eddy-current sensing for rotating machinery protection.
  • Category: 8 mm Proximity Probe
  • Key Specs: M10 x 1 mounting thread | 1.0 m armored cable | Miniature coaxial ClickLoc connector
  • Condition: New Original (New Surplus) / Refurbished, subject to stock confirmation

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

Model Number Breakdown:

Code Description
330104 3300 XL 8 mm probe, M10 x 1 thread, with armor
00 Unthreaded length: 0 mm
05 Overall case length: 50 mm
10 Total probe cable length: 1.0 m
02 Miniature coaxial ClickLoc connector, standard cable
00 Agency approval option: not required

 

3. Key Technical Specifications

Parameter Technical Specification
Manufacturer Bently Nevada
Model 330104-00-05-10-02-00
Product Series 3300 XL 8 mm
Product Type Eddy-current proximity probe
Probe Tip Diameter 8.0 mm
Mounting Thread M10 x 1
Probe Case Length 50 mm
Unthreaded Length 0 mm
Integrated Cable Length 1.0 m (3.3 ft)
Cable Construction Armored, standard cable configuration
Connector Miniature coaxial ClickLoc
Measurement Principle Non-contact eddy-current sensing
Linear Measurement Range 2.0 mm (80 mils)
Standard Sensitivity 7.87 V/mm (200 mV/mil), with compatible system components
Frequency Response 0–10 kHz, +0/-3 dB
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel
Operating Temperature -52°C to +177°C (-62°F to +350°F)
Calibration Target AISI 4140 steel

System compatibility note: The probe operates as part of a complete 3300 XL proximity transducer system with a compatible Proximitor Sensor. The 1.0 m configuration is a probe-only system length and does not require an extension cable. When replacing a probe in an existing 5 m or 9 m system, verify the total electrical length and matching components before ordering.

 

4. Product Introduction

The Bently Nevada 330104-00-05-10-02-00 is an 8 mm eddy-current proximity probe from the 3300 XL series. It measures the distance between the probe tip and a conductive rotating target, converting shaft movement into an electrical signal for vibration and position monitoring.

This configuration features an M10 x 1 threaded case, 50 mm case length, 1-meter armored cable, and miniature coaxial ClickLoc connector. It is suitable for applications requiring compact metric mounting and mechanical protection of the probe cable.

330104-00-05-10-02-00

330104-00-05-10-02-00

330104-00-05-10-02-00

330104-00-05-10-02-00

330104-00-05-10-02-00

330104-00-05-10-02-00

5. Application Scenarios & Field Experience

Rotating machinery requires accurate shaft-position and vibration measurements to identify developing mechanical problems. A proximity probe provides the non-contact measurement interface between the rotating shaft and the machinery protection system. Incorrect thread dimensions, cable length, or connector configuration can result in installation problems or an unsuitable transducer system.

1. Power Generation – Steam Turbine Shaft Monitoring
Measures shaft vibration and relative shaft position at fluid-film bearing locations. These measurements help identify abnormal shaft movement and potential bearing-related problems.

2. Oil & Gas – Centrifugal Compressor Monitoring
Provides non-contact shaft displacement measurements for high-speed rotating equipment. Continuous vibration monitoring helps maintenance teams assess changes in machine condition.

3. Petrochemical Processing – Pump Bearing Monitoring
Monitors shaft movement in critical process pumps, supporting the detection of vibration changes associated with imbalance, misalignment, or bearing deterioration.

4. Industrial Machinery – Axial Position Monitoring
Measures shaft displacement for applications where axial movement is an important machinery protection parameter. The probe’s mounting dimensions and measurement configuration must match the installation design.

Illustrative engineering scenario, not a documented customer installation.

A maintenance team identifies an abnormal vibration reading on a compressor bearing monitor. During inspection, technicians check the probe mounting, cable condition, connector interface, and sensor gap before replacing the suspected probe. They also verify the complete transducer system length and target material. This process helps distinguish a defective probe from installation or system-configuration issues.

 

6. Standard Operating Procedure (SOP) for Quality Control

1. Visual & Origin Inspection

  • Verify the complete part number: 330104-00-05-10-02-00.
  • Inspect the 8 mm probe tip, M10 x 1 threaded case, cable armor, and ClickLoc connector.
  • Check for corrosion, damaged threads, cable deformation, and connector contamination.
  • Review available OEM labels, packaging, and traceability information.

2. Electrical & Functional Testing

  • Where suitable test equipment is available, measure probe resistance between the center and outer conductors.
  • For the 1-meter probe, compare the measured resistance with the OEM nominal value of approximately 7.59 Ω, subject to the specified tolerance.
  • Inspect cable continuity and insulation condition.
  • Where a compatible Proximitor Sensor and calibrated test target are available, verify the output response across the measurement range.
  • Do not treat a resistance check alone as proof of complete operating performance.

3. Firmware Verification

  • Firmware verification is not applicable to this passive proximity probe.
  • Verify the associated Proximitor Sensor model, total system length, and target-material calibration instead.
  • Confirm that the installed monitoring system is configured for the correct transducer arrangement.

4. ESD-Safe Packaging

  • Protect the probe connector and exposed contacts from electrostatic and mechanical damage.
  • Keep the probe cable loosely coiled without exceeding its minimum bend radius.
  • Use protective packaging to prevent damage to the threaded case, sensing tip, and cable armor.

5. Pre-Shipment Documentation

  • Record the full model number and visible identification details.
  • Provide actual product photographs upon request.
  • Document the inspection scope and electrical test results where testing has been performed.
  • Confirm the supplied cable length, connector type, and physical condition before shipment.

 

7. Frequently Asked Questions (FAQ)

Q1: Can the 330104-00-05-10-02-00 replace other 3300 XL 8 mm proximity probes?

A: Not automatically. Although 3300 XL components support interchangeability within specified system configurations, mounting thread, cable length, armor, and connector options must match the installation. This model uses an M10 x 1 thread and a 1-meter cable. Verify the existing probe configuration before replacement.

Q2: What warranty is available for this proximity probe?

A: We offer a 12-month warranty, subject to confirmed order terms. The supplied condition and warranty coverage will be specified in the quotation and order confirmation.

Q3: Is the 330104-00-05-10-02-00 available for immediate shipment?

A: Availability and condition must be confirmed against current inventory. For confirmed available stock, the standard arrangement is shipment within one week after payment. Contact us with your required quantity for a current quotation.

Q4: Can a firmware mismatch affect this probe’s operation?

A: The probe itself does not contain user-configurable firmware. However, the Proximitor Sensor, monitoring system configuration, and total transducer system length must be compatible. Incorrect system length or target-material calibration can affect measurement accuracy.

Q5: What should engineers check before installing this probe?

A: Verify the M10 x 1 mounting thread, 50 mm case length, mounting depth, cable routing, connector condition, and required measurement gap. Also confirm the Proximitor Sensor and total system length. The 1-meter configuration does not require an extension cable. Follow the OEM installation instructions and approved machinery isolation procedures before installation or adjustment.