Sale!

GE IS420ESWBH2A | Industrial Network Switch, Fast Shipping

Original price was: 8.500,00 ر.س.Current price is: 7.000,00 ر.س.

  • Model: IS420ESWBH2A
  • Brand: GE (General Electric)
  • Series: Mark VIe / Mark VIeS Control Systems
  • Core Function: Provides industrial Ethernet switching for communication between Mark VIe controllers, distributed I/O modules, and control network devices.
  • Category: Industrial Ethernet Switch / IONet Switch
  • Key Specs: 16 × 10/100Base-TX RJ45 Ports | 2 × 100Base-FX Multimode Fiber Ports | Redundant 18–36 VDC Power Inputs
  • Condition: New Original (New Surplus) / Refurbished, subject to stock confirmation

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Key Technical Specifications

Parameter Value
Manufacturer GE
Model Number IS420ESWBH2A
Functional Abbreviation ESWB
Product Type Unmanaged Industrial Ethernet / IONet Switch
Compatible Platforms Mark VIe / Mark VIeS
Copper Ethernet Ports 16 × 10/100Base-TX
Fiber Optic Ports 2 × 100Base-FX
Fiber Type Multimode
Fiber Connector LC
Ethernet Standards IEEE 802.3, 802.3u, 802.3x
Duplex Mode Full/Half Duplex Auto-Negotiation
Power Supply Redundant 18–36 VDC inputs
Nominal Voltage 24/28 VDC
Maximum Current 1 A
Power Architecture Dual inputs with diode-OR redundancy
Packet Buffer Minimum 256 KB
MAC Address Table 4K addresses
Operating Temperature -40 to +70°C
Cooling Natural convection
Mounting DIN Rail
Protection Industrial control panel installation

 

Technical references: GE Mark VIe Industrial Ethernet / IONet Switch Summary Sheet GEI-100869A and GEH-6725R Controller and Switch Instructions. Verify the applicable hardware revision and installation requirements before replacement.

quicktimeonline.com+2

 

Product Introduction

The GE IS420ESWBH2A is an unmanaged industrial Ethernet switch designed for GE Mark VIe and Mark VIeS turbine control systems. It provides 16 copper Ethernet ports and two 100 Mbps multimode fiber-optic uplinks with LC connectors, supporting communication across distributed control and I/O networks.

Its redundant DC power inputs, packet buffering, and full-duplex switching architecture make it suitable for industrial control environments requiring continuous network communication. Unlike a general-purpose Ethernet switch, the ESWB series is specifically approved for Mark VIe IONet applications.

quicktimeonline.com+1

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

IS420ESWBH2A

Application Scenarios & Field Experience

Part 1 – Engineering Challenges

In a turbine control system, network communication is part of the control infrastructure. Controllers must exchange data with distributed I/O modules and other network devices without introducing unnecessary communication delays or packet loss.

A failed IONet switch can interrupt communication between control components, potentially resulting in I/O communication faults or controller alarms.

The IS420ESWBH2A addresses this requirement through 16 copper Ethernet connections and two multimode fiber uplinks. Its redundant power inputs also allow the switch to remain powered if one of the supported DC supply sources fails.

Here is the catch: not every industrial Ethernet switch is suitable for a Mark VIe control network. GE specifies approved IONet switches for these applications. Substituting an unapproved commercial switch can prevent I/O modules from receiving controller outputs.

ManualsLib+1

Part 2 – Typical Application Scenarios

1. Power Generation – Gas Turbine Control Systems

  • Process: Gas turbine monitoring, protection, and control.
  • Requirement: Connects distributed I/O networks and control components through the Mark VIe IONet infrastructure.

2. Combined-Cycle Power Plants – Turbine Control Integration

  • Process: Gas turbine and associated plant control systems.
  • Requirement: Provides copper and fiber Ethernet connections for distributed control network communication.

3. Industrial Power Generation – Steam Turbine Automation

  • Process: Turbine monitoring, auxiliary equipment control, and protection.
  • Requirement: Supports Ethernet communication between compatible Mark VIe control system components.

4. Oil & Gas – Turbine-Driven Compressor Stations

  • Process: Gas compression and turbine-driven equipment monitoring.
  • Requirement: Provides industrial Ethernet switching for compatible turbine control and distributed I/O networks.

Part 3 – Illustrative Field Case

A power generation facility experienced intermittent IONet communication alarms affecting several distributed I/O connections. During troubleshooting, engineers identified abnormal link behavior associated with an existing ESWB network switch. A replacement IS420ESWBH2A was sourced to match the original port configuration, including its two multimode fiber uplinks. After checking the fiber connections, redundant DC supplies, and network link indicators, the affected communication paths were restored.

Illustrative engineering scenario, not a documented customer installation.

 

Standard Operating Procedure (SOP) for Quality Control

Our QC process for the GE IS420ESWBH2A focuses on hardware identification, Ethernet port integrity, fiber interfaces, and redundant power operation.

1. Visual & Origin Inspection

  • Verify the GE identification label and complete model number: IS420ESWBH2A.
  • Inspect the switch housing, PCB, and terminal connections.
  • Check all 16 RJ45 Ethernet ports for physical damage.
  • Inspect both multimode fiber-optic LC connectors.
  • Check OEM labels, serial numbers, and available packaging.
  • Inspect for corrosion, burned components, unauthorized repairs, or physical damage.
  • Record the actual hardware revision and product condition.

2. Live Rig Testing

  • Verify the required 18–36 VDC input range.
  • Check both redundant power inputs independently.
  • Verify power status and LED indications.
  • Test RJ45 port link status and Ethernet connectivity.
  • Check both 100Base-FX multimode fiber interfaces using compatible fiber test equipment.
  • Verify link activity, speed, and duplex indications.
  • Where a suitable test setup is available, check packet transmission and reception across connected ports.

3. Firmware Verification

  • The is an unmanaged Ethernet switch.
  • It does not use conventional user-installable PLC firmware.
  • Record hardware identification and revision information.
  • Verify the exact switch model against the GE-approved IONet configuration.
  • Confirm that the supplied version matches the required fiber-port configuration.
  • Document any hardware differences before shipment.

4. ESD-Safe Packaging

  • Handle electronic assemblies using ESD-protected procedures.
  • Place the switch in anti-static packaging.
  • Protect RJ45 and fiber-optic connectors against dust and mechanical impact.
  • Use protective caps for fiber interfaces where applicable.
  • Add suitable cushioning for international transportation.
  • Verify the model number and shipping label before dispatch.

5. Pre-Shipment Documentation

  • Provide actual product photographs upon request.
  • Arrange live video inspection before shipment.
  • Confirm product condition, quantity, and hardware identification.
  • Provide packing information and shipping tracking after dispatch.

 

Frequently Asked Questions (FAQ)

Q1: Is the GE compatible with all GE Mark VIe controllers?

A: The is an approved ESWB-series IONet switch for compatible Mark VIe and Mark VIeS control network configurations.

However, compatibility depends on the system architecture and approved network design. Before ordering, confirm the existing switch model, fiber type, connector configuration, and network topology.

Do not substitute an ordinary industrial Ethernet switch without checking GE’s IONet requirements.

Q2: What warranty do you provide for the GE ?

A: We offer a 12-month warranty, subject to confirmed order terms. The warranty covers qualifying product-related failures under normal operating conditions. Physical damage, incorrect wiring, and unauthorized modifications are excluded.

Q3: Is the GE available from stock, and how quickly can it ship?

A: Availability and condition are subject to actual inventory confirmation. We can provide product photographs and arrange live video inspection before shipment.

For confirmed available inventory, our standard shipping arrangement is generally within one week after payment. International shipping can be arranged with tracking information.

Q4: Does the require firmware matching when replacing an existing switch?

A: No conventional firmware matching is required because the is an unmanaged Ethernet switch.

However, hardware configuration must match. Pay particular attention to:

  • 16 copper Ethernet ports.
  • 2 × 100Base-FX multimode fiber ports.
  • LC fiber connectors.
  • Redundant DC power connections.
  • GE-approved IONet network configuration.

A visually similar ESWBH model may have a different fiber configuration. For example, the IS420ESWBH3A has 16 copper ports but no fiber uplinks. These models should not be treated as interchangeable without checking the network design.

ManualsLib+1

Q5: What should engineers check before installing the ?

A: Check the following before installation:

  • Confirm the correct model and fiber-port configuration.
  • Verify the DC supply voltage is within 18–36 VDC.
  • Check both redundant power connections and polarity.
  • Confirm multimode fiber compatibility and LC connector condition.
  • Inspect RJ45 Ethernet cables and port connections.
  • Verify the existing IONet network topology.
  • Check link, activity, speed, and duplex indicators after installation.
  • Confirm communication with the connected control system components.

Important: Do not disconnect active IONet connections without evaluating the network redundancy and operational impact. Removing a switch can interrupt communication with connected I/O devices and potentially cause controller alarms or process trips. Follow the approved GE maintenance procedure and establish the required process safety conditions before replacement.

zyq xuanchuance