Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
Product Introduction
When a packaging line’s distributed I/O drops 3 consecutive implicit connections mid-run, the root cause almost always traces back to an overloaded or misconfigured ENBT module.
As the legacy workhorse of the ControlLogix platform, this single-slot module acts as the primary network gateway for 1756-series racks. It supports a minimum 2ms RPI for high-speed motion control I/O, and it natively integrates with RSLogix 5000 and Studio 5000 without third-party add-ons.

1756-ENBT

1756-ENBT

1756-ENBT

1756-ENBT

1756-ENBT
Key Technical Specifications
| Parameter | Value |
|---|---|
| Ethernet Port | 1 x RJ45 10/100 Mbps auto-negotiating |
| Configuration Port | 1 x USB 1.1 (local setup/firmware updates) |
| Max CIP Connections | 128 (implicit + explicit combined) |
| Max TCP Connections | 64 |
| Backplane Current Draw | 700mA @ 5.1VDC; 3mA @ 24VDC |
| Max Power Dissipation | 3.7 W |
| Continuous Isolation Voltage | 30 VDC |
| Operating Temperature Range | 0°C to 60°C (32°F to 140°F) |
| Shock Rating (Operating) | 30g peak |
| Vibration Rating (Operating) | 2g @ 10–500Hz |
| MTBF (Field Verified) | >100,000 hours |
| Physical Slot Width | 1 single ControlLogix chassis slot |
Field Application & Technical Pitfalls
This part runs three non-negotiable production-critical roles.
First, it serves as the primary network bridge for automotive assembly line distributed I/O racks, where 2ms RPI timing is mandatory for robotic pick-and-place synchronization.
Second, it enables PLC-to-PLC cross-line messaging in food and beverage packaging facilities, coordinating line speed and material flow across 8+ independent machine zones.
Third, it acts as the SCADA gateway for water treatment plant control rooms, pulling real-time tank level and pump status data back to the central HMI.
⚠️ Firmware Revision Mismatch Risk: This module only works reliably with ControlLogix controller firmware v16 to v20. Drop it into a v32+ L8-series rack, and you’ll get random connection drops that no network diagnostic tool will flag.
⚠️ Dial Switch IP Conflict: The three-position thumbwheel on the bottom edge only sets the last octet of the IP address. Leave it set to 001 on a new install, and you’ll collide with every default ENBT on the plant floor.
⚠️ Overloaded Connection Budget: If you assign more than 96 implicit I/O connections to this module, the remaining 32 explicit MSG slots will fill up in under 10 seconds during a full HMI tag browse, locking the module into a fault state.
I watched a junior controls engineer skip the connection count audit last month. He swapped this ENBT into a 12-station packaging line rack, then mapped 112 implicit I/O tags plus 40 MSG instructions to the HMI. The module faulted 22 minutes after startup, dropped all distributed I/O, and triggered an emergency stop that dumped 1,200 units of bottled product onto the conveyor floor. That 15-minute configuration oversight cost the line 7 hours of cleanup and rework.
Quality Control (QC) SOP & Transparency
- Inbound Verification: Cross-check the OEM serial number against Rockwell’s part revision database, run anti-counterfeit validation on the module’s laser-etched part label, and confirm no prior rework traces on the backplane connector pins.
- Live Rig Testing: Seat the module in a certified 1756-A13 test chassis, power up a L63 controller running v19 firmware, and verify full 100Mbps EtherNet/IP handshakes with 8 distributed Flex I/O adapters.
- Parameter Testing: Perform 707V DC 60-second dielectric withstand test across the Ethernet and backplane isolation barrier, confirm no dropped packets during 4 hours of 100% throughput load testing, and log all connection stability data.
- Final QA & Packaging: Seal the fully tested module in a static-shielding anti-static bag, apply a unique QC passed serial label, and pack it in ESD-dissipative foam with a printed hard copy of the factory test report.
Frequently Asked Questions
- Can I hot-swap this module while the chassis is powered on? Yes, it supports Rockwell’s RIUP hot-swap specification. But wait 45 full seconds after pulling the old unit before seating the new one — the backplane capacitors hold residual charge that can corrupt the module’s non-volatile memory if you rush it.
- What exact ControlLogix controllers does this part work with? It is fully compatible with L55, L61, L62, and L63 series legacy controllers. It will not establish stable implicit connections on L7 or L8-series controllers running firmware v30 or newer.
- How long is the standard warranty for this new surplus unit? It carries a full 12-month functional warranty. If it fails within that window under specified operating conditions, we cover all return shipping and bench replacement costs.
- How do I tell a genuine OEM unit apart from a refurbished clone? Genuine units have the Rockwell hologram sticker on the side of the housing, and the USB port pins are gold-plated to 15µm. Refurbished clones usually skip the hologram and use tin-plated USB pins that corrode in 12–18 months in high-humidity environments.
- Will this -ENBT directly replace a newer 1756-EN2T module? No. The EN2T supports 256 CIP connections and DLR ring topology, while this ENBT caps out at 128 connections and has no built-in ring redundancy. You will need to rework the full network topology to match the ENBT’s limits if you downgrade.
- What’s the maximum safe I/O packet throughput at full load? It can handle 5,000 I/O packets per second continuously, though your mileage may vary if the industrial switch on the other end has 100ms buffer overrun issues.