Sale!

GE IC697MDL653 | 24 VDC Positive Logic Output Card

Original price was: 1.000,00 ر.س.Current price is: 500,00 ر.س.

  • Model: IC697MDL653
  • Brand: GE Fanuc (GE Intelligent Platforms)
  • Series: Series 90-70 discrete output family — confirm the rack and slot on the label
  • Core Function: Switches 24 VDC field loads through 32 positive-logic outputs under program control.
  • Category: Discrete DC output module
  • Key Specs: 32 output points in four groups of eight; 24 VDC positive logic; 0.5 A per point class — verify exact rating and total module current with the OEM datasheet
  • Condition: New Original (New Surplus) / Refurbished

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

3. Product Introduction

As a 32-point DC output card for the Series 90-70 rack, the IC697MDL653 drives 24 VDC loads with positive-logic switching in four isolated groups of eight. It occupies a single backplane slot and maps to the CPU through the rack configuration. The group isolation matters in panels where one eight-point bank feeds solenoids on a different supply rail than the next bank (—though your mileage may vary depending on module revision). Replacement speed is the real edge when a bank of outputs goes dead.

IC697MDL653

IC697MDL653

IC697MDL653

IC697MDL653

IC697MDL653

IC697MDL653

IC697MDL653

4. Key Technical Specifications

Parameter Value
Catalog Number IC697MDL653
Brand GE Fanuc
Product Type Series 90-70 discrete DC output module
Host Platform Series 90-70 rack, single slot — confirm slot restrictions in the rack manual
Output Points 32, arranged in four groups of eight — verify grouping with OEM datasheet
Output Type 24 VDC positive logic, sourcing
Output Current 0.5 A per point class — verify exact per-point and total module current with OEM datasheet
Load Voltage Range 24 VDC nominal — verify exact operating window with OEM datasheet
Isolation Group-to-group and group-to-backplane — verify exact values with OEM datasheet
Backplane Current Verify exact draw with OEM datasheet
Configuration Rack configuration file; output mapping must match the slot
Operating Temperature Verify exact range with OEM datasheet
Hot Swap Confirm permission in the OEM manual before live removal

 

5. Field Application & Technical Pitfalls (The Engineer’s Guide)

Where this module is critical:

  • Packaging and assembly lines driving solenoid valve banks where 32 outputs sit in one rack slot.
  • Material handling cells with diverter solenoids, small pilot valves, and indicator lamps on 24 VDC.
  • Water and wastewater plants where remote 90-70 racks operate pilot devices on a DC control bus.

Three pitfalls that bite during replacement:

  • Total module current versus per-point rating. Warning: 0.5 A per point does not mean 16 A for the whole card. The module has a total current limit and a group limit, and a replacement that carries a heavy bank on one group will run hot or shut down. Add up the simultaneous loads per group, not just per point.
  • Sourcing output versus sinking field device. Warning: this is a positive-logic sourcing card. A field device wired for a sinking (negative-logic) module will not switch correctly, and the wiring may look correct at the terminal strip. Confirm the field device common against the OEM drawing.
  • Group supply, fusing, and hot-swap permission. Warning: each group of eight typically needs its own supply and fuse. A missing group fuse leaves eight outputs dead while the card looks healthy. Do not assume live removal is allowed for your slot — remove rack power, ground yourself, and confirm the edge connector is fully seated before energizing.

Lesson learned: A technician replaced a failed output card, powered up, and watched one bank of eight solenoids stay dead. Root cause: the group fuse on that bank had opened during the original fault, and nobody checked it. The card was good; the fuse was not. Twenty minutes of troubleshooting for a two-minute meter check.

 

6. Quality Control (QC) SOP & Transparency

  1. Inbound Verification. Each module is checked against the OEM packing list, label typography, serial number format, and date-code range. Revision suffix and connector condition are logged before the unit enters stock.
  2. Live Rig Testing. The module is seated in a compatible 90-70 test rack with a CPU and a load bank. We power on, confirm rack recognition, and switch each of the 32 outputs through a resistive load while measuring voltage drop and continuity.
  3. Parameter Testing. Per-point output voltage under load, group isolation, and backplane current draw are checked against the OEM datasheet where published. Undocumented values are flagged for buyer confirmation rather than guessed.
  4. Final QA & Packaging. The module ships in an anti-static bag with a QC-passed label, a test record showing the revision and output readings we verified, and photos of the terminal layout when available.

 

7. Frequently Asked Questions (FAQ)

Can I hot-swap this module in a live 90-70 rack? Do not assume so. Some 90-70 slots support live removal, but the OEM manual and your site procedure decide. If live removal is not explicitly permitted for that slot, remove rack power first.

How do I confirm it matches my rack? Send the rack model, CPU firmware revision, slot number, old module label photo, and terminal wiring photos. We cross-check the catalog number and test record before shipping. Exact fit still depends on the OEM support matrix for your CPU firmware.

What’s the warranty? 12 months from delivery for functional failure under normal operation. Terminal blocks and fuses, if present, carry a 90-day replacement guarantee.

How can I tell genuine OEM from refurbished? Genuine units carry the original GE Fanuc label with consistent typography and a traceable serial number. Refurbished units carry our QC tag in addition to the OEM label, and we disclose condition on the quote.

Does it ship with a terminal block? The module is the card only unless the quote says otherwise. Confirm your existing terminal block part number before ordering.

Will it drive a 24 VDC solenoid directly? Only if the solenoid’s steady-state and inrush current sit inside the per-point and group limits with margin. Add a suppression diode across the coil, because a missing snubber shortens contact life and can fault the output driver.

What’s the difference between this and a sinking DC output card? This one sources positive voltage to the load. A sinking card pulls the load to ground. Mixing the two in one panel without checking the field device common is the fastest way to a non-working output bank.

What do you need to quote the right replacement? Rack model, CPU firmware, slot number, old label photo, and terminal wiring photos. That five-minute upload prevents most wrong-part returns.

zyq xuanchuance