Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
Product Introduction
When a material handling system’s control valve drifts 3% off setpoint randomly because a generic analog output module lacks proper galvanic isolation, the root cause almost always traces back to a unit that cannot block 50Hz ground loop noise.
Purpose-built for GE Field Control and RX7i PACSystem platforms, this module delivers 8 isolated analog voltage output channels grouped into two independent 4-channel isolation banks. Its 14-bit DAC ensures high-precision signal generation, and every channel supports independent auto-scaling configuration. It integrates seamlessly into GE PACSystem racks without requiring external signal conditioners.

GE IC670ALG310

GE IC670ALG310

GE IC670ALG310

GE IC670ALG310

GE IC670ALG310
Key Technical Specifications
| Parameter | Value |
|---|---|
| Number of Output Channels | 8 (2 isolated groups of 4) |
| Output Voltage Range | -10 V to +10 V (overrange up to ±10.25 V) |
| D/A Resolution | 14-bit |
| Minimum Load Resistance | 5 kΩ |
| Galvanic Isolation Rating | 250 V RMS |
| User Power Supply | 24 V DC external |
| Bus Interface Current Draw | 170 mA |
| Full Scale Accuracy | ±0.1% typical at 25°C |
| Operating Temperature Range | 0°C to +60°C |
| Advanced Features | Per-channel auto-scaling, individual channel enable/disable |
| Diagnostic Functions | Over/under range detection, user power loss monitoring |
| Country of Origin | USA |
| Net Weight | ~454 g |
Field Application & Technical Pitfalls
This part runs three non-negotiable production-critical roles.
First, it acts as the primary analog output interface for refinery flow control valves, delivering stable -10V to +10V positioning signals that maintain precise process flow rates.
Second, it delivers accurate speed reference signals for large conveyor system variable frequency drives, enabling smooth ramp-up and ramp-down control to prevent material spillage.
Third, it serves as the analog drive layer for packaging line tension control systems, maintaining consistent web tension across 8 independent unwinder/rewinder stations.
⚠️ Load Resistance Under 5kΩ Risk: Each output channel requires a minimum 5kΩ load resistance. If you connect a 2kΩ actuator directly to the channel, you will exceed the module’s current drive capability and cause 5–10% output drift.
⚠️ Isolation Group Misalignment: Channels 1–4 and 5–8 are two separate isolated banks. If you connect a field device referenced to different ground potentials across the two groups, you will create a ground loop that damages the isolation barrier.
⚠️ PACSystem Firmware Compatibility Gap: This module only works with RX7i PACSystem firmware v9.5 or newer. Drop it into an older RX3i system, and the backplane communication handshake will fail, disabling all 8 output channels.
I watched a junior automation tech skip the load resistance check last quarter. He connected a 2kΩ proportional valve directly to one channel of this module, and the output drifted 8% off setpoint. The packaging line’s web tension went completely unstable, and 120 meters of film product had to be scrapped. That 1-minute configuration oversight forced the team to rework all 8 output channel wiring to add external signal amplifiers.
Quality Control (QC) SOP & Transparency
- Inbound Verification: Cross-check the OEM serial number against GE Fanuc’s official part revision database, run anti-counterfeit validation on the module’s laser-etched serial label, and confirm no prior rework traces on the analog output stage solder joints.
- Live Rig Testing: Mount the module in a certified RX7i PACSystem test rack, connect 8 calibrated 5kΩ load resistors, and verify full -10V to +10V output tracking across 4 hours of continuous operation.
- Parameter Testing: Perform 300V AC 60-second dielectric withstand test across each isolation group and chassis ground, confirm every channel reads within ±0.1% accuracy, and log all overrange detection response time data.
- Final QA & Packaging: Seal the fully tested module in a static-shielding anti-static bag, apply a unique QC passed serial label, and pack it in ESD-dissipative foam with a printed hard copy of the full calibration test report.
Frequently Asked Questions
- Can I hot-swap this module while the PACSystem rack is powered on? No. The Field Control backplane does not support hot-swap. Pulling the module live will cut all analog outputs instantly, triggering uncontrolled actuator coasting.
- What exact GE PLC systems does this part work with? It is fully compatible with GE Field Control and RX7i PACSystem platforms running firmware v9.5 or newer. It will not establish stable communication on older Series 90-70 PLC systems.
- How long is the standard warranty for this new surplus unit? It carries a full 12-month functional warranty. If it fails within that window under specified operating conditions, we cover all return shipping and bench replacement costs.
- How do I tell a genuine OEM unit apart from a refurbished clone? Genuine units have the GE Fanuc hologram sticker on the side of the PCB, and every output channel uses a precision 14-bit DAC chip marked with GE part number. Refurbished clones usually skip the official hologram and use generic 12-bit DACs that cannot deliver the rated accuracy.
- Will this IC670ALG310 directly replace an older GE 4-channel analog output module? No. The older variant only supports 4 channels, while this unit extends that to 8. You will need to reconfigure all output channel scaling parameters in the PACSystem control software after swapping.
- What’s the maximum safe continuous operating temperature at full 8-channel load? It will hold ±0.1% full scale accuracy up to 60°C, though your mileage may vary if the rack cooling airflow drops below 15 CFM and internal component temperatures spike 15°C above ambient.