Allen-Bradley 1769-L32CA | Rockwell Automation CompactLogix Core Processor Module

Original price was: 999,00 ر.س.Current price is: 888,00 ر.س.

  • ‌Model‌: 1769-L32CA (Base model: 1769-L32C)
  • ‌Brand‌: Allen-Bradley (Rockwell Automation)
  • ‌Series‌: CompactLogix 1769 Modular Controller Line
  • ‌Core Function‌: Flagship mid-range modular processor for Allen-Bradley CompactLogix small-to-medium PLC systems, acting as the core control computing hub, realizing stable execution of medium-scale industrial control programs, supporting Modbus RTU serial communication, and ensuring the reliable operation of small and medium-sized industrial automation equipment.
  • ‌Category‌: CompactLogix 1769 Series PLC Central Processing Unit
  • ‌Key Specs‌: 750KB built-in user memory, DIN rail mounting withstands 20g operating shock, panel mounting withstands 30g operating shock, 0~60°C operating temperature, Modbus RTU/RS-232/RS-485 serial communication, US origin
  • ‌Condition‌: New Original (New Surplus)

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Product Introduction

When your Allen-Bradley CompactLogix small-to-medium industrial automation system needs a highly reliable dedicated mid-range control core to stably execute medium-scale industrial control programs, this module acts as the system’s central computing hub.
It is a flagship industrial-grade modular processor from Allen-Bradley 1769-L32CA series, specially designed for CompactLogix small and medium-sized PLC control scenarios. It is equipped with 750KB built-in user memory, which can fully carry medium-capacity industrial control programs and process data, and can meet the control requirements of up to 16 local 1769 I/O modules. It supports Modbus RTU, RS-232 and RS-485 serial communication protocols, which can seamlessly interconnect with various on-site industrial sensors, frequency converters and third-party serial devices. Its industrial-grade rugged mechanical design: DIN rail mounting can withstand 20g operating shock, panel mounting can withstand 30g operating shock, and the operating temperature range covers 0~60°C, which can adapt to various harsh industrial installation environments. It supports level signal measurement, monitoring and control, and can realize remote I/O data acquisition and intelligent building control functions. Its compact modular design can be easily installed in the limited electrical cabinet space of small and medium-sized equipment, making it a core replacement part for Allen-Bradley CompactLogix PLC system maintenance and retrofit projects in small manufacturing, intelligent building and logistics equipment industries.

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

1769-L32CA

Key Technical Specifications

Parameter Value
Part Number 1769-L32CA (Base Model: 1769-L32C)
Product Type CompactLogix 1769 Series PLC Central Processing Unit
Manufacturer Allen-Bradley (Rockwell Automation)
Country of Origin United States
Core Function Medium-scale industrial control program execution, serial device interconnection, remote I/O data acquisition
Built-in User Memory 750 KB
Maximum Supported Local I/O Modules 16 1769 series I/O modules
Mounting Method DIN Rail / Panel Mounting
DIN Rail Mount Operating Shock Resistance 20 g
Panel Mount Operating Shock Resistance 30 g
Operating Temperature Range 0 ~ 60 °C (32 ~ 140 °F)
Supported Communication Protocols Modbus RTU, RS-232, RS-485 Serial Communication
Core Application Scenarios Level signal measurement, industrial automation control, intelligent building control, security engineering
Compatible Systems Allen-Bradley CompactLogix 1769 PLC Platforms, Rockwell Automation Small Industrial Control Systems
Warranty 12 months from delivery

 

Field Application & Technical Pitfalls

Critical Industrial Scenarios

  • **Small Manufacturing Production Line Medium-Scale Process Control: Acts as the core processing unit for small factory CompactLogix systems, realizing stable and high-speed execution of medium-scale production control programs, ensuring the upper control system accurately grasps the real-time operation status of all production links.
  • **Intelligent Building Automation System Central Control Computing: Delivers reliable high-performance control performance for intelligent building CompactLogix systems, adapting to long-term continuous operation environments, meeting the high-reliability control requirements of intelligent building HVAC and lighting systems.
  • **Small Logistics Sorting Equipment Motion Control: Adapts to strict continuous operation industrial environments, providing stable high-speed program execution support for small logistics sorting equipment CompactLogix automation systems.

Non-Negotiable Technical Pitfalls

  • ‌⚠️ Bold Warning 1‌: Never arbitrarily connect the serial communication port to a non-industrial-grade device that exceeds the maximum load limit. The third serial channel will experience overcurrent that causes the internal communication circuit to burn out.
  • ‌⚠️ Bold Warning 2‌: Skipping the pre-commissioning full 20g shock resistance continuous operation test will leave you with hidden program operation crash risks. This module must confirm the full shock resistance performance fully meets CompactLogix system specifications before putting into operation.
  • ‌⚠️ Bold Warning 3‌: Do not arbitrarily use non-matching non-industrial-grade serial communication cables for device connection. Improper cable shielding performance will cause the Modbus RTU data transmission to drop packets frequently and trigger system communication alarms.

A small manufacturing plant maintenance team once swapped an Allen-Bradley 1769-L32CA module and skipped the full shock resistance test. The hidden installation fixing error caused the module to crash during equipment operation, resulting in the production line being interrupted for 1 hour.

 

Quality Control (QC) SOP & Transparency

  1. ‌Inbound Verification‌: Cross-check the OEM serial number against Rockwell Automation’s official CompactLogix part registry, confirm the part number 1769-L32CA matches the factory label, and inspect no damage or oxidation on all serial communication ports and backplane connectors.
  2. ‌Live Rig Testing‌: Power the unit in a calibrated Allen-Bradley CompactLogix PLC system test bench, simulate full medium-scale industrial control program continuous operation scenarios, and confirm full 2-hour continuous stable operation.
  3. ‌Parameter Testing‌: Verify the 750KB memory full-load operation performance meets factory specifications, confirm the Modbus RTU serial communication performance meets industrial PLC control standards, and validate all on-board LED status indicators work properly.
  4. ‌Final QA & Packaging‌: Seal the tested module in a static-shielding anti-static bag, attach a unique QC passed serial label, and nest it in foam padding inside a rigid industrial shipping carton.

 

Frequently Asked Questions (FAQ)

  • ‌Can I hot-swap this module while the CompactLogix PLC system is running?‌ No. You must first confirm that the redundant control path is operating normally and the system is in a safe no-load state, then perform the replacement operation after cutting off the module power, otherwise you will trigger unexpected system control interruption risks.
  • ‌What exact systems is this module compatible with?‌ It works natively with Allen-Bradley CompactLogix 1769 PLC platforms, and can seamlessly connect with all standard 1769 series I/O modules, no custom adaptation is required.
  • ‌How long is the standard warranty for this new surplus unit?‌ 12 months from delivery. It covers all manufacturing defects, but does not extend to units damaged by miswiring, overcurrent load, or improper control program configuration in the field.
  • ‌How do I tell a genuine OEM unit apart from a refurbished clone?‌ Genuine Allen-Bradley 1769-L32CA modules have a laser-etched part number on the PCB, not a printed sticker. Clone units almost always fail the full 2-hour medium-scale control program continuous operation stability test.
  • ‌What is the typical lead time for shipment?‌ In-stock units ship within 48 hours. If you require official Rockwell factory PLC controller performance test documentation, add 2 extra business days to the turnaround window.
  • ‌Can this module replace the older Allen-Bradley legacy CompactLogix PLC CPU?‌ Well, technically it fits the same standard slot installation footprint, but you must confirm the CompactLogix system firmware version fully supports the module before replacement to ensure 100% system compatibility.
zyq xuanchuance