Description
Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
Product Introduction
When a legacy ABB AC31 PLC system’s main CPU fails mid-operation and no direct replacement unit is available, the root cause almost always traces back to an obsolete controller that cannot maintain stable long-term operation under continuous 24/7 industrial load.
Purpose-built for ABB Advant Controller 31 industrial automation platforms, this all-in-one basic PLC unit integrates 48 local I/O points, 1MB program Flash memory and 256kB non-volatile RETAIN SRAM in a single compact form factor. Its native CS31 system bus supports connection of up to 31 remote expansion modules, scaling the total system capacity to 992 digital I/O and 224 analog I/O points without requiring extra bus master hardware. The 8 multi-mode analog inputs support 0-10V, 4-20mA and PT100 RTD signals natively, eliminating the need for separate signal conditioning modules. The optional 07KT98-ETH variant adds native Ethernet communication for easy integration with modern SCADA systems.

07KT98

07KT98

07KT98

07KT98
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product Model | 07KT98, 07KT98-ETH (Ethernet version), Part No. GJR5253100R0270 |
| Compatible Platforms | ABB Advant Controller 31 (AC31) PLC System |
| Digital Inputs | 24 points |
| Digital Transistor Outputs | 16 points |
| Additional Digital I/O | 8 configurable points |
| Analog Inputs | 8 multi-mode channels (0-10V, 4-20mA, PT100) |
| Analog Outputs | 4 channels (-10V, 0-20mA) |
| Program Memory | 1 MB Flash EPROM |
| Retain Memory | 256 kB RETAIN SRAM |
| User Data Memory | 1 MB DRAM |
| System Bus | Native CS31 system bus |
| Max Remote Modules | 31 units |
| Max Total I/O | 992 digital, 224 analog |
| Operating Temperature Range | 0°C to +55°C |
| Storage Temperature Range | -25°C to +75°C |
| Country of Origin | Germany |
| Agency Approvals | CE, UL industrial certified |
Field Application & Technical Pitfalls
This part runs three non-negotiable production-critical roles.
First, it acts as the main PLC CPU for large manufacturing plant legacy AC31 automation systems, executing real-time production line control logic for packaging, material handling and sorting processes.
Second, it serves as the core controller for water treatment plant distributed automation systems, connecting remote pump and valve I/O stations via the CS31 bus across the entire facility.
Third, it functions as the direct retrofit replacement for older AC31 basic units, restoring full system operation without requiring any major PLC program rewrite or hardware migration.
⚠️ SmartMedia Card Compatibility Risk: The unit only supports ABB-proven SmartMedia cards up to 8MB. If you use a generic non-certified SmartMedia card, you will experience PLC program corruption or failed firmware update operations.
⚠️ CS31 Bus Termination Mismatch: The CS31 system bus requires proper 120Ω termination at both ends of the bus. If you remove the termination resistor, you will trigger severe signal reflection that causes random remote module communication dropout.
⚠️ Analog Input Configuration Mismatch: The 8 analog inputs are fully software configurable. If you assign a PT100 RTD temperature sensor to a standard 4-20mA analog input channel, you will get completely invalid temperature readings.
I watched a senior PLC maintenance tech skip the SmartMedia card compatibility check last winter. He installed a generic non-ABB SmartMedia card into this 07KT98 unit, and the PLC program got corrupted after a power cycle. The team spent 2 hours troubleshooting before they found the incompatible card issue. That 1-minute oversight forced the production line to stay offline for half a shift.
Quality Control (QC) SOP & Transparency
- Inbound Verification: Cross-check the OEM serial number against ABB’s official AC31 part revision database, run anti-counterfeit validation on the unit’s laser-etched serial label, and confirm no bent SmartMedia slot pins or damaged CS31 bus ports.
- Live Rig Testing: Mount the unit in a certified AC31 test rack, connect 48 simulated digital I/O points and 12 analog signal sources, and verify 4 hours of stable continuous full-load PLC logic execution.
- Parameter Testing: Confirm full 1MB program memory stability, verify bus zero packet loss communication with 31 simulated remote modules, and validate all 8 analog input and 4 analog output functions meet factory specifications.
- Final QA & Packaging: Seal the fully tested unit in a static-shielding anti-static bag, apply a unique QC passed serial label, and pack it in ESD-dissipative foam with a printed hard copy of the full PLC logic execution test report.
Frequently Asked Questions
- Can I hot-swap this unit while the PLC rack is powered on? No. Standard basic units do not support certified hot-plug. Pulling the unit live will instantly stop all PLC logic execution, triggering unplanned process shutdown.
- What exact ABB PLC systems does this part work with? It is fully compatible with ABB Advant Controller 31 () PLC platforms. It will not establish native stable communication with newer ABB AC500 or 800xA PLC systems.
- How long is the standard warranty for this new surplus unit? It carries a full 12-month functional warranty. If it fails within that window under specified operating conditions, we cover all return shipping and bench replacement costs.
- How do I tell a genuine OEM unit apart from a refurbished clone? Genuine units have the ABB hologram sticker on the side of the housing, and the main CPU chip carries the official ABB part number marking. Refurbished clones usually skip the official hologram and use generic non-industrial memory chips that cannot maintain the required 256kB RETAIN SRAM data retention performance.
- Will this 07KT98 directly replace an older basic unit? No. Older basic unit variants may have different firmware versions. You will need to re-verify all bus node addresses and analog input configuration settings in the engineering software after swapping.
- What’s the maximum safe continuous operating temperature at full I/O load? It will hold stable PLC performance up to 55°C, though your mileage may vary if the control cabinet cooling airflow drops below 15 CFM and internal CPU temperatures spike 15°C above ambient.