ABB REF541KM118AAAA | 48-250V DC / 100-240V AC Multi-Protocol Mid-Voltage Feeder Terminal

Original price was: 4.500,00 ر.س.Current price is: 3.200,00 ر.س.

  • Model: REF541KM118AAAA
  • Brand: ABB
  • Series: REF541 Mid-Voltage Feeder Protection & Control Terminal Platform
  • Core Function: All-in-one panel-mounted multi-protocol feeder protection relay that integrates overcurrent protection, ground fault detection, local PLC interlock logic and IEC 61850 substation communication in a single compact unit, eliminating the need for separate protection relays, RTUs and protocol gateways for mid-voltage switchgear bays
  • Category: Mid-Voltage Feeder Protection & Control Terminal
  • Key Specs: 1kHz 3-phase sampling, 200 IEC 61131-3 logic blocks, dual redundant IEC 61850 GOOSE ports, 48-250V DC / 100-240V AC universal auxiliary power
  • Condition: New Original (New Surplus)

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Product Introduction

When a mid-voltage substation’s feeder protection system fails to clear a phase fault within 50ms, the root cause almost always traces back to a fragmented setup with separate relays, RTUs and gateways that cannot synchronize their fault response timing.

Purpose-built for industrial plants, utility substations and renewable energy collection bays, this all-in-one feeder terminal runs a 32-bit DSP that samples 3-phase current and voltage at 1kHz. It executes 16 independent protection stages while still supporting 200 IEC 61131-3 logic blocks that previously required a separate remote terminal unit. Its universal wide-range auxiliary power input works directly with station battery banks without extra DC-DC converters, and dual redundant Ethernet ports maintain continuous IEC 61850 GOOSE communication even if one network link fails. The 250mm wide compact chassis fits perfectly into existing standard switchgear cutouts left by old electromechanical relays.

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

REF541KM118AAAA

Key Technical Specifications

Parameter Value
Product Model REF541KM118AAAA
Product Series ABB REF541 Feeder Protection Terminal
Voltage Inputs 3 × 100–690 V AC, fully software configurable
Current Inputs 3 × 1 A / 5 A, software selectable
Sampling Rate 1 kHz 3-phase simultaneous sampling
Protection Functions 50/51, 50N/51N, 49, 27/59, 81O/U, 46, 67N, 50BF, 87L (optional)
Logic Capacity 200 function blocks, 16 timers, 16 latches
Communication Protocols IEC 61850-8-1, Modbus TCP, SPA, LON, DNP3, PROFIBUS (slot)
Auxiliary Power 48–250 V DC / 100–240 V AC, max 15W
Operating Temperature Range -40°C to +70°C
Sealing Rating Front IP54, Rear IP20
Dimensions 250 mm × 200 mm × 110 mm
Net Weight 2.1 kg
Agency Approvals CE, UL, DNV marine certified

 

Field Application & Technical Pitfalls

This part runs three non-negotiable production-critical roles.
First, it acts as the core protection unit for utility 36kV metal-clad switchgear feeder bays, delivering overcurrent, ground fault and breaker failure protection while pushing metering data directly to the distribution management system via IEC 61850.
Second, it serves as the all-in-one protection relay for industrial plant 6.6kV large motor and capacitor bank feeders, using undervoltage protection to ride through voltage sags caused by large chiller startup.
Third, it functions as the feeder protection terminal for wind farm and solar park 33kV collection bays, blocking turbine reconnection until grid voltage and frequency stability windows are fully satisfied.

‌⚠️ CT Ratio Configuration Mismatch Risk‌: The current input supports both 1A and 5A secondary CTs via software selection. If you set the wrong CT ratio, all protection pickup thresholds will be off by a factor of 5, causing either false tripping or failure to trip during real faults.
‌⚠️ GOOSE Communication Redundancy Gap‌: The two Ethernet ports must be assigned to separate logical subnets. If you put both ports on the same subnet, you will create a routing loop that breaks all IEC 61850 GOOSE inter-bay protection communication.
‌⚠️ Power Supply Overvoltage Risk‌: The universal auxiliary power input can only handle up to 250V DC. If you connect it directly to a 270V DC station battery system, you will blow the internal power regulation circuit instantly.

I watched a senior substation protection tech skip the CT ratio check last winter. He installed this REF541KM118AAAA relay on a 5A secondary CT feeder, accidentally left the software setting on 1A, and the overcurrent protection pickup threshold was 5 times lower than intended. The relay tripped randomly every time the feeder hit normal full load current, and the team spent 2 hours troubleshooting before they found the configuration error. That 1-minute oversight forced the plant to run the feeder on manual bypass protection for half a shift.

 

Quality Control (QC) SOP & Transparency

  1. ‌Inbound Verification‌: Cross-check the OEM serial number against ABB’s official REF541 part revision database, run anti-counterfeit validation on the relay’s laser-etched serial label, and confirm no physical damage or cracked terminals on the current/voltage input connectors.
  2. ‌Live Rig Testing‌: Mount the relay in a certified protection test rack, connect a 3-phase secondary injection test set, and verify 4 hours of stable protection operation across all 16 protection stages.
  3. ‌Parameter Testing‌: Confirm 1kHz sampling accuracy, verify all protection pickup thresholds are within ±1% of set values, and validate dual-port IEC 61850 GOOSE communication stability with zero packet loss.
  4. ‌Final QA & Packaging‌: Seal the fully tested relay in a static-shielding anti-static bag, apply a unique QC passed serial label, and pack it in shock-absorbent foam with a printed hard copy of the full secondary injection test report.

 

Frequently Asked Questions

  • ‌Can I hot-swap this relay while the switchgear bay is energized?‌ No. You must put the feeder into full de-energized bypass mode before removing the relay, otherwise you will lose all protection for that bay and create a serious safety hazard.
  • ‌What exact ABB protection systems does this part work with?‌ It is fully compatible with ABB REF541 series protection platforms. It will not establish native stable IEC 61850 communication with older REF542plus or REF543 variants without full configuration migration.
  • ‌How long is the standard warranty for this new surplus unit?‌ It carries a full 12-month functional warranty. If it fails within that window under specified operating conditions, we cover all return shipping and bench replacement costs.
  • ‌How do I tell a genuine OEM unit apart from a refurbished clone?‌ Genuine units have the ABB hologram sticker on the rear of the housing, and the 32-bit DSP chip carries the official ABB part number marking. Refurbished clones usually skip the official hologram and use generic lower-performance DSPs that cannot deliver the rated 1kHz sampling accuracy.
  • ‌Will this REF541KM118AAAA directly replace an older ABB REF541 feeder protection relay?‌ No. Older REF541 variants may have different firmware versions. You will need to re-verify all protection pickup thresholds and IEC 61850 data point mapping after swapping.
  • ‌What’s the maximum safe continuous operating temperature at full 1kHz sampling load?‌ It will hold stable protection performance up to 70°C, though your mileage may vary if the switchgear compartment internal temperature spikes above 75°C and the conformal coated PCB will experience accelerated aging.