Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
3. Product Introduction (Anti-Template)
Standalone indexing axes still appear on packaging machines, rotary tables, and simple positioning stations. The 2098-DSD-020X handles those jobs without requiring a full motion controller or network interface.
It accepts single-phase 100-240 VAC, delivers up to 2 kW continuous at 230 V, and includes the indexing firmware that lets the drive execute stored move profiles on its own. Plants that standardized on the Ultra 3000 platform years ago keep this catalog number on the critical-spares list because a failed drive can stop an entire station until a replacement is installed.

2098-DSD-020X

2098-DSD-020X

2098-DSD-020X

2098-DSD-020X

2098-DSD-020X
4. Key Technical Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 100–240 V AC rms, single-phase |
| Input Frequency | 47–63 Hz |
| Nominal Input Current | 18 A rms |
| Continuous Output Power | 1.0 kW (115 VAC) / 2.0 kW (230 VAC) |
| Continuous Output Current | 10 A (0-peak) |
| Peak Output Current | 30 A (0-peak) |
| Bus Overvoltage | 400 V DC |
| Bus Capacitance | 1880 µF |
| Features | Indexing |
| Auxiliary Logic Supply | External 12/24 V DC required for I/O |
| Operating Temperature | 0 °C to 55 °C |
| Approximate Weight | 2.1–2.24 kg |
5. Field Application & Technical Pitfalls (The Engineer’s Guide)
This drive commonly powers indexing rotary tables, simple pick-and-place axes, and packaging machine feeders that do not need coordinated multi-axis motion. The built-in indexing capability allows stored move profiles to run without a separate motion controller.
Three pitfalls appear during replacement:
Logic power omission – the drive requires an external 12/24 V DC supply for the I/O section; omitting it leaves the digital inputs and outputs dead even though the power stage is live.
Feedback cable and shield grounding – improper shield termination or mixed encoder wiring produces position errors that only appear under load.
Fusing and branch-circuit protection – the drive is rated for specific Class J or Class CC fuses; using the wrong type can delay clearing of a fault or nuisance-trip the upstream breaker.
One plant installed a surplus unit and spent half a shift chasing “no response” on the digital inputs. The external 24 V logic supply had been left disconnected; once it was restored the indexing sequences ran immediately.
6. Quality Control (QC) SOP & Transparency
- Inbound Verification – OEM labeling, series, and date codes are photographed and matched to the packing list; any evidence of prior field use is documented.
- Live Rig Testing – drive is powered with both AC mains and auxiliary logic supply, then exercised with a known-good motor and feedback cable through basic enable, jog, and indexing moves.
- Parameter Testing – bus voltage, current limits, and fault response are verified; serial communication and digital I/O are checked.
- Final QA & Packaging – unit is sealed in an anti-static bag with desiccant, fitted with a QC-passed label showing test date and technician ID, then double-boxed for shipment.
7. Frequently Asked Questions (FAQ)
Does the 2098-DSD-020X include network connectivity?
No. This catalog number is the base indexing model without DeviceNet or SERCOS. Network versions carry the –DN or –SE suffix.
What external power does the I/O section need?
An external 12/24 V DC supply is required for the digital inputs, outputs, and logic. The main AC input alone does not power the I/O.
Can this drive run three-phase motors?
Yes. The output stage is three-phase even though the input is single-phase.
Is this drive still in production?
The Ultra 3000 family has been discontinued. Replacement units come from surplus or refurbished stock. Migration paths exist to Kinetix platforms when a full redesign is planned.
What warranty comes with a new-surplus unit?
Twelve months from shipment against defects in materials and workmanship when installed within the published ratings.
How do I confirm the drive is healthy after installation?
Apply both AC and logic power, verify the status display, enable the drive with a known-good motor and feedback cable, and execute a short indexing move while monitoring current and position error.