Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
Product Introduction
When an industrial backup generator fails to synchronize with the main utility grid during a critical power outage, the root cause almost always traces back to a discrete protection relay setup that cannot maintain precise phase angle matching under fluctuating load conditions.
Purpose-built for Rockwell Automation Logix family PLC systems, this microprocessor-based module integrates all core generator control, protection and synchronization functions in a single chassis. It supports 3-phase generator sensing with built-in cross current compensation, delivering stable 50/60Hz operation across a wide range of generator sizes. The dual redundant ControlNet interface ensures zero single-point network failure, maintaining continuous real-time generator data transmission to the Logix PLC even if one ControlNet communication link is completely lost. The thumbwheel switches on the front panel allow quick and easy ControlNet node address (MAC ID) configuration without requiring dedicated engineering software for basic network setup.

1407-CGCM

1407-CGCM
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product Model | 1407-CGCM |
| Compatible Platforms | Rockwell Automation Logix Family Programmable Controllers |
| Power Supply | 18–32 V DC (24 V DC nominal) |
| Typical Power Consumption | 30 W |
| Generator Sensing Input | 3-phase with cross current compensation |
| Supported Frequency | 50 / 60 Hz |
| Current Input Range | 1 A or 5 A max selectable |
| Voltage Sensing Range | 57–208 V AC |
| Voltage Metering Accuracy | ±0.2% full scale |
| Frequency Metering Range | 10–90 Hz |
| Frequency Metering Accuracy | ±0.05 Hz |
| Communication Interfaces | Dual redundant ControlNet, host firmware rev 4.25, ControlNet firmware rev 1.07 |
| Operating Temperature Range | -20°C to +70°C |
| Vibration Rating | 10–500 Hz, 5.0 g |
| Relative Humidity | 5% to 95% non-condensing |
| Agency Approvals | CE, UL industrial generator control certified |
| Country of Origin | USA |
| Net Weight | ~7.7 kg |
Field Application & Technical Pitfalls
This part runs three non-negotiable production-critical roles.
First, it acts as the core generator control and synchronization unit for large manufacturing plant backup power systems, ensuring seamless and glitch-free generator-to-utility grid transfer during main power outage events.
Second, it serves as the protection and metering module for data center redundant generator paralleling systems, delivering high-precision real-time electrical parameter monitoring for all connected backup generators.
Third, it functions as the direct retrofit replacement for older Allen-Bradley generator control modules, restoring full generator protection functionality without requiring any major Logix PLC system hardware migration.
⚠️ Current Input Range Mismatch Risk: The module supports selectable 1A or 5A current input. If you connect a 5A rated generator current transformer to the module configured for 1A input, you will permanently damage the internal current sensing circuit.
⚠️ ControlNet Node Address Conflict Risk: The thumbwheel switches set the ControlNet MAC ID. If two modules on the same ControlNet bus are assigned the exact same node address, you will trigger severe network conflict that causes all connected devices to lose communication.
⚠️ AC Sensing Voltage Overrange: The maximum allowable AC voltage sensing input is 208V AC. If you connect it directly to a 480V generator output without a proper step-down potential transformer, you will instantly destroy the module’s voltage sensing circuit.
I watched a senior power system tech skip the current input range check last summer. He installed this 1407-CGCM module on a backup generator, accidentally set the current input to 1A while the generator CT was rated 5A, and the module’s internal current sensing circuit burned out immediately after power-up. The team spent 2 hours troubleshooting before they found the configuration mismatch. That 1-minute oversight forced the plant to run without backup generator protection for an entire shift.
Quality Control (QC) SOP & Transparency
- Inbound Verification: Cross-check the OEM serial number against Rockwell Automation’s official Logix part revision database, run anti-counterfeit validation on the module’s laser-etched serial label, and confirm no cracked current/voltage sensing terminals or damaged ControlNet ports.
- Live Rig Testing: Mount the module in a certified Logix PLC test rack, connect 3-phase simulated generator voltage and current signal sources, and verify 4 hours of stable continuous generator synchronization operation.
- Parameter Testing: Confirm ±0.2% voltage metering accuracy, verify dual redundant ControlNet zero packet loss communication, and validate all generator protection and synchronization functions meet factory specifications.
- Final QA & Packaging: Seal the fully tested module in a static-shielding anti-static bag, apply a unique QC passed serial label, and pack it in ESD-dissipative foam with a printed hard copy of the full generator control performance test report.
Frequently Asked Questions
- Can I hot-swap this module while the Logix PLC rack is powered on? No. Standard industrial generator control modules do not support certified hot-plug. Pulling the module live will instantly cut all generator protection and synchronization functions, leaving the generator completely unprotected.
- What exact Rockwell Automation systems does this part work with? It is fully compatible with Rockwell Automation Logix family PLC platforms. It will not establish native stable communication with older non-Logix Allen-Bradley PLC-5 or SLC 500 systems.
- How long is the standard warranty for this new surplus unit? It carries a full 12-month functional warranty. If it fails within that window under specified operating conditions, we cover all return shipping and bench replacement costs.
- How do I tell a genuine OEM unit apart from a refurbished clone? Genuine units have the Allen-Bradley hologram sticker on the side of the PCB, and the main generator control microprocessor carries the official Rockwell Automation part number marking. Refurbished clones usually skip the official hologram and use generic lower-accuracy sensing circuits that cannot deliver the rated ±0.2% voltage metering accuracy.
- Will this 1407-CGCM directly replace an older Allen-Bradley generator control module? No. Older generator control variants may have different firmware versions. You will need to re-verify all generator protection parameter settings and ControlNet node address configuration in the RSLogix 5000 engineering software after swapping.
- What’s the maximum safe continuous operating temperature at full load? It will hold stable generator control performance up to 70°C, though your mileage may vary if the control cabinet cooling airflow drops below 15 CFM and internal sensing circuit temperatures spike 15°C above ambient.