Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.
3. Product Introduction
As a PPD113-family power supply module, the PPD113B03-26-100110 turns cabinet input into a regulated rail for control hardware. It mounts in the designated position and feeds the modules downstream. The long suffix is not decoration — it encodes output and option details, and a same-family spare can fit mechanically while sitting outside your load budget. Verify input range, output rating, and derating against the OEM datasheet before you order (—though your mileage may vary depending on cabinet airflow).

PPD113B03-26-100110

PPD113B03-26-100110

PPD113B03-26-100110
4. Key Technical Specifications
| Parameter | Value |
|---|---|
| Catalog Number | PPD113B03-26-100110 |
| Brand | ABB |
| Product Type | Power supply module |
| Series | PPD113 family — confirm suffix code on label |
| Input Voltage | Verify exact AC or DC range and configuration with OEM datasheet |
| Output Voltage | Set by suffix code — verify nominal and adjustment range |
| Output Current | Set by suffix code — verify rating and derating curve |
| Output Power | Verify exact wattage and load profile with OEM datasheet |
| Ripple and Noise | Verify limits with OEM datasheet |
| Protection | Verify overvoltage, overcurrent, and thermal behavior with OEM datasheet |
| Mounting | Cabinet or rack position — verify terminal and fastener layout |
| Cooling | Verify convection or forced-air requirements and clearance |
| Operating Temperature | Verify exact range and derating with OEM datasheet |
5. Field Application & Technical Pitfalls (The Engineer’s Guide)
Where this supply is critical:
- Control cabinets feeding relays, pilot devices, and interface modules where a rail sag drops half the panel.
- Process skids with solenoid banks and small drives that pull hard during pickup and need supply headroom.
- Legacy ABB installations kept alive because the process side runs fine and a controls upgrade is a capital project, not a maintenance order.
Three pitfalls that bite during replacement:
- Suffix code and output mismatch. Warning: the base model can match while the suffix changes output voltage, current limit, or option set. A supply that powers up on the bench can still run a cabinet at the wrong rail or trip under load. Compare the full label, not the first eight characters.
- Input configuration and breaker coordination. Warning: a unit set for a different input range can energize and fail in the cabinet — or nuisance-trip the upstream breaker on inrush. Confirm site voltage, jumper or tap settings, and breaker curve against the OEM drawing before mounting it.
- Residual charge, load sharing, and terminal torque. Warning: input filter capacitors can hold a charge after the disconnect opens. Meter the terminals, then ground yourself before touching the chassis. In redundant arrangements, match output settings and verify sharing after power-up. Torque the output terminals to the OEM spec, because a loose screw heats under load and looks like a failing supply.
Lesson learned: A technician replaced a failed supply with a spare set for a higher input range. The cabinet fed the lower voltage. The unit powered up, ran for a few minutes, then dropped the rail. Root cause — nobody checked the input configuration against the site voltage. The supply was good; the setting was not. One unplanned outage later, the work order gained a voltage verification step.
6. Quality Control (QC) SOP & Transparency
- Inbound Verification. Each supply is checked against the OEM packing list, label typography, full suffix, serial number format, and date-code range. Input configuration and output rating are logged before the unit enters stock.
- Live Rig Testing. The supply is mounted on a bench fixture with a variable input source and a resistive load bank. We power on at rated input, confirm the output, and run it under load while logging voltage and ripple.
- Parameter Testing. Output regulation, ripple, input current draw, insulation resistance, and terminal condition are checked against the OEM datasheet where published. Undocumented values are flagged for buyer confirmation rather than guessed.
- Final QA & Packaging. The supply ships in protective packaging with a QC-passed label, a test record showing the input configuration and output voltage we verified, and photos of the terminal layout when available.
7. Frequently Asked Questions (FAQ)
Can I hot-swap this supply in a live cabinet? No. Remove input power and confirm the rail is discharged before replacement. Live swapping can arc the input terminals or drop the rail to every module on the panel.
How do I confirm it matches my cabinet? Send the old label photo, input voltage, load list, ambient temperature, and terminal wiring photos. We cross-check the suffix and test record before shipping. Exact fit still depends on the OEM datasheet for derating and clearance.
What’s the warranty? 12 months from delivery for functional failure under normal operation. Fuses and other consumables carry a 90-day replacement guarantee.
How can I tell genuine OEM from refurbished? Genuine units carry the original ABB label with consistent typography and a traceable serial number. Refurbished units carry our QC tag in addition to the OEM label, and we disclose condition on the quote.
Does it ship with a configuration file? No. We ship a test record, not a cabinet file. Confirm the input and output settings against the OEM drawing for your application.
What is the actual load capacity? The suffix code sets output voltage and current, but the real limit depends on ambient temperature and airflow. Verify the load budget against the OEM datasheet before you size a replacement.