Sale!

ABB TVB3101-1ISC | 1308-644957-12 Industrial Synchronization Module, Fast Shipping

Original price was: 5.200,00 ر.س.Current price is: 4.300,00 ر.س.

  • Model: TVB3101-1ISC (1308-644957-12)
  • Brand: ABB
  • Series: VME Bus Control Card
  • Core Function: Delivers high-speed pulse generation and timing synchronization for drive systems
  • Category: VME Control Board
  • Key Specs: VMEbus interface | 50kHz max output | -20°C to +60°C operating range
  • Condition: New Original (New Surplus) / Refurbished

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

Key Technical Specifications

Parameter Value
Bus Interface VMEbus, standard 6U form factor
Reference Part Number 1308-644957-12
Clock / Output Frequency Up to 50 kHz programmable pulse output
Supply Voltage 220 V AC auxiliary supply
Operating Temperature −20 °C to +60 °C
Mechanical Form 6U VME rack mount
Onboard Diagnostics Front panel status LEDs, fault flag registers
EMC Compliance CE marked, built for heavy industrial EMI environments
Shock & Vibration Designed for turbine and machinery vibration exposure
Weight 2.3 kg
Signal Type Differential pulse and synchronization signals

 

Product Introduction

The ABB TVB3101-1ISC is a legacy 6U VME control board built for precision timing and pulse output. It links host VME processors to variable-speed drives and turbine governor subsystems. It handles synchronized pulse sequencing and closed-loop timing feedback. The VME architecture lets it slot into existing rack assemblies, and its onboard diagnostics cut the time spent isolating timing drift issues in older turbine control platforms.

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

TVB3101-1ISC

Application Scenarios & Field Experience

Many legacy turbine control systems rely on dedicated VME timing cards. Standard analog I/O boards cannot maintain stable, phase-aligned pulse signals across load swings. This card generates the synchronized drive pulses that keep governor and excitation loops locked at the required phase angle.

  1. Thermal power plants: Steam turbine governor control racks, speed pulse synchronization.
  2. Steel rolling mills: Multi-stand drive synchronization for continuous strip production.
  3. Petrochemical compressor trains: Variable-speed motor drive pulse sequencing.
  4. Hydroelectric facilities: Generator excitation and gate position timing control.

In my experience, a coal-fired power unit had a TVB3101-1ISC develop intermittent pulse jitter after years of thermal cycling. The maintenance team swapped the spare VME card into the empty slot, loaded the timing register parameters, and verified pulse phase alignment on an oscilloscope before returning the governor to automatic mode. The turbine stayed stable, and no load runback occurred.

 

Standard Operating Procedure (SOP) for Quality Control

  • Visual & Origin Inspection: Inspect PCB traces, VME edge connector pins, solder joints, and front panel LEDs. Flag boards with cracked traces or corroded connector fingers.
  • Live Rig Testing: Install in VME test chassis, apply rated AC supply, validate programmable pulse output across the full frequency range, confirm fault LED operation.
  • Firmware / Register Verification: Record the onboard firmware revision and default timing register map. Confirm the revision matches the site’s control program.
  • ESD-Safe Packaging: Fit protective edge cover on the VME connector, place in static shielding bag, secure with foam supports inside a rigid carton.

 

Frequently Asked Questions (FAQ)

Q1: Can TVB3101-1ISC mix with other VME cards in the same rack? A: It works alongside compatible VME processor and I/O cards. Confirm the backplane and host software support its register mapping. Mismatched VME master firmware can cause timing corruption. Q2: What warranty applies to this ABB TVB3101-1ISC? A: We offer a 12-month warranty. Warranty covers hardware defects under rated operating conditions. Damage from ESD, overvoltage pulses, or misconfigured VME backplane termination is excluded. Q3: Is this exact TVB3101-1ISC variant stocked? A: This is a legacy VME spare. Stock status changes often. Confirm lead time before scheduling turbine outage windows. Functional substitutes are not approved for most turbine governor schemes. Q4: Can I adjust pulse frequency and phase settings on the fly? A: All timing parameters are written through the VME bus by the host control processor. Settings do not persist on the board itself after power loss. Save your control logic file before replacement. Q5: Can I hot-swap this VME board while the rack is powered? A: Do not hot-swap this VME card. The VME backplane lacks hot-swap protection. Removal will drop timing pulses and trigger a governor trip or drive fault.