Sale!

GE Fanuc IC695CPE310 | RX3i Controller, Replacement CPU

Original price was: 999,00 ر.س.Current price is: 888,00 ر.س.

  • Model: IC695CPE310
  • Brand: GE Fanuc
  • Series: PACSystems RX3i
  • Core Function: 1.0 GHz CPU for RX3i logic, Ethernet comms, and I/O control
  • Category: CPU Module
  • Key Specs: 1.0 GHz processor | 10 MB user memory | Ethernet + serial ports
  • Condition: New Original (New Surplus) / Refurbished

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

3. Key Technical Specifications

Parameter Value
Model IC695CPE310
Brand GE Fanuc
Series PACSystems RX3i
Processor 1.0 GHz Intel Celeron M
User Memory 10 MB
Data Memory 10 MB
Communication Ports 2 x 10/100 Ethernet; 1 x RS-232; 1 x RS-485 (verify by revision)
Backplane RX3i PCI backplane
Max Local I/O Up to 32 modules (rack dependent)
Programming Software Proficy Machine Edition
Protocols SRTP, Modbus TCP, Ethernet Global Data (EGD)
Operating Temperature 0 to 60°C
Certifications UL, cUL, CE, Class I Div 2
Power Requirements 3.3 VDC and 5 VDC from backplane
Firmware V7.0 or later (verify exact revision)

 

4. Product Introduction

The GE Fanuc IC695CPE310 is a PACSystems RX3i CPU module. It executes ladder, function block, and structured text logic, manages local I/O, and handles Ethernet and serial communications. The 1.0 GHz processor and 10 MB user memory support mid-to-large RX3i applications without replacing existing racks or I/O.

In my experience, the CPE310 fits projects where older CPU310 or CPE305 modules hit memory or scan-time limits. It uses the same RX3i backplane and Proficy Machine Edition workflow. Verify exact firmware compatibility with your existing project before ordering.

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

IC695CPE310

5. Application Scenarios & Field Experience

A continuous process line loses production when a CPU faults and spare parts are not stocked. The CPE310 addresses this by providing a drop-in RX3i controller for legacy racks. It keeps existing I/O, wiring, and HMI communications intact, so recovery focuses on restoring logic and firmware rather than rewiring cabinets.

  1. Water/Wastewater: lift station pump control — requires RX3i CPU for Modbus TCP to SCADA and local I/O for pump interlocks.
  2. Automotive: assembly conveyor — uses Ethernet Global Data to coordinate VFDs and safety I/O; CPE310 handles deterministic scan.
  3. Oil & Gas: compressor station — needs serial RS-485 for legacy meters and Ethernet for HMI; CPE310 bridges both.
  4. Power Generation: balance-of-plant — replaces CPU310 when memory capacity is exceeded; keeps existing RX3i I/O.

A food processing plant had an RX3i line stop at 2 AM. The CPU310 would not clear a memory fault. The maintenance team had a spare IC695CPE310 on the shelf. They restored the Proficy Machine Edition project, matched firmware, and the line ran before the next shift.

 

6. Standard Operating Procedure (SOP) for Quality Control

  • Visual & Origin Inspection: Check OEM seals, labels, date codes, and anti-counterfeit markings against known reference images.
  • Live Rig Testing: Power-on self-test, backplane communication, Ethernet link, and serial protocol handshakes on a configured RX3i rack.
  • Firmware Verification: Document exact firmware revision, boot firmware, and any project compatibility notes before packing.
  • ESD-Safe Packaging: Anti-static bag, foam support, and labeled box with handling instructions to prevent static damage.

 

7. Frequently Asked Questions (FAQ)

Q1: Will IC695CPE310 work as a direct replacement for IC695CPU310?
A: Not always direct. It fits the same RX3i backplane, but you must verify firmware, Proficy Machine Edition version, and project hardware configuration. Some older projects need a firmware upgrade or I/O module revision check. Don’t hot-swap without redundancy or you risk a system trip.

Q2: What warranty do you offer?
A: 12 months on the IC695CPE310. It covers functional defects under normal use. It does not cover improper installation, reversed backplane power, or firmware corruption from unauthorized changes.

Q3: Is it in stock and how fast does it ship?
A: Stock varies by revision and condition. We list real inventory on our website. Orders usually ship within 1–2 business days after payment and export documentation. For critical downtime, ask for a live stock check before ordering.

Q4: What if my project uses a different firmware revision?
A: Firmware mismatch is a real risk. The CPE310 may ship with a newer revision than your Proficy Machine Edition expects. Back up your project, confirm the CPU firmware revision, and update the project or CPU as needed. If you cannot match it, contact technical support before installation.

Q5: Any installation pitfalls?
A: Yes. Power down the rack before inserting the module. Confirm backplane power and slot compatibility. Don’t hot-swap this without redundancy or you risk a system trip. After power-up, check Ethernet IP, serial settings, and I/O scan before going online.