Sale!

Eaton XVS-440-10MPI-1-1AD | Genuine OEM Panel PC

Original price was: 5.000,00 ر.س.Current price is: 4.000,00 ر.س.

  • Model: XVS-440-10MPI-1-1AD
  • Brand: Eaton
  • Series: XVS-440 industrial HMI panel PC family — confirm the suffix options on the label
  • Core Function: Runs the local operator visualization and connects the screen to a controller over the MPI interface.
  • Category: Industrial HMI panel PC
  • Key Specs: 10-inch class TFT display; MPI controller interface per suffix; 24 VDC nominal supply — verify exact resolution, processor, and interface set with the OEM datasheet
  • Condition: New Original (New Surplus) / Refurbished

Description

Note: Many products are not yet listed. Please contact us for more product information. Our supply channels are constantly expanding, and we currently have 20 stable shared supply channels. Please confirm the model, product, price, and all other necessary information with customer service before placing an order. We offer new, refurbished, and used products, and prices are adjusted according to the year of the item you require.

 

3. Product Introduction

As a 10-inch class HMI panel in Eaton’s XVS-440 line, the XVS-440-10MPI-1-1AD puts the operator screen and the local runtime in one panel-mount unit. It connects to a controller over MPI, runs the visualization project stored on the unit, and fits a standard cabinet cutout. The suffix after the base model decides the interface and option set, so match the full order code before you swap (—though your mileage may vary depending on runtime version and project file).

 

4. Key Technical Specifications

Parameter Value
Catalog Number XVS-440-10MPI-1-1AD
Brand Eaton
Product Type Industrial HMI panel PC
Display Size 10-inch class TFT — verify exact size and resolution with OEM datasheet
Touch Type Verify resistive or capacitive touch with OEM datasheet
Processor / Memory Verify exact processor and memory with OEM datasheet
Controller Interface MPI per model suffix — confirm baud rate and connector type
Additional Interfaces Verify Ethernet, USB, and serial options from the suffix code
Supply Voltage 24 VDC nominal — verify exact range and tolerances
Mounting Panel mount — confirm cutout dimensions and clearance
Configuration Tool Eaton HMI runtime and project editor — match runtime version to the project
Operating Temperature Verify exact range with OEM datasheet

 

5. Field Application & Technical Pitfalls (The Engineer’s Guide)

Where this panel is critical:

  • Packaging and assembly lines where the operator needs recipe selection, fault reset, and cycle counts at the machine, not at a remote desk.
  • Water and wastewater stations where a local panel shows pump status and alarm history during rounds.
  • Machine tools and test stands where MPI remains the controller link and a panel swap must preserve the existing project.

Three pitfalls that bite during replacement:

  • Runtime version and project file mismatch. Warning: a replacement panel with a newer runtime can reject the project file or change screen behavior. Load the site project and verify the runtime version before you mount the unit. Well, technically the panel may boot with the old project, but the runtime can still fail on startup.
  • MPI address, baud rate, and bus termination. Warning: a panel set to a duplicate MPI address or the wrong baud rate will power up and show a communication fault. Confirm the address and bus settings against the old unit and the network drawing. Check termination at the physical ends of the segment.
  • 24 VDC supply common, panel cutout, and ESD. Warning: reversed supply polarity or a shared common with the wrong reference can damage the unit or cause erratic touch behavior. Confirm the terminal pair against the OEM drawing. Ground yourself before handling the panel, and verify the cutout and gasket before tightening the mounting clips.

Lesson learned: A technician replaced a failed panel with a spare that carried the right display size but a different runtime build. The unit powered up, showed the project, and then dropped the MPI connection every few minutes. Root cause — the runtime version did not match the project’s communication driver. The panel was good; the runtime was not. One shift of troubleshooting for a five-minute version check.

 

6. Quality Control (QC) SOP & Transparency

  1. Inbound Verification. Each panel is checked against the OEM packing list, label typography, full order code, serial number format, and date-code range. Fitted interface options are logged before the unit enters stock.
  2. Live Rig Testing. The panel is powered on a bench fixture at rated 24 VDC supply, booted to the runtime, and checked for display output, touch response, and interface recognition. MPI communication is exercised where the test fixture supports it.
  3. Parameter Testing. Supply current draw, backlight operation, touch calibration, and interface continuity are checked against the OEM datasheet where published. Undocumented values are flagged for buyer confirmation rather than guessed.
  4. Final QA & Packaging. The panel ships in protective packaging with a QC-passed label, a test record showing the runtime and interface options we verified, and photos of the label and connector layout when available.

 

7. Frequently Asked Questions (FAQ)

Can I hot-swap this panel while the machine is running? No. Remove 24 VDC supply and confirm the controller link is isolated before replacement. Live swapping can fault the MPI segment or corrupt the runtime.

How do I confirm it matches my existing unit? Send the full label photo, project file name, runtime version, MPI address, and a picture of the panel cutout. We cross-check the order code and test record before shipping. Exact fit depends on the full suffix, not just the display size.

What’s the warranty? 12 months from delivery for functional failure under normal operation. Mounting hardware and other consumables carry a 90-day replacement guarantee.

How can I tell genuine OEM from refurbished? Genuine units carry the original Eaton label with consistent typography and a traceable serial number. Refurbished units carry our QC tag in addition to the OEM label, and we disclose condition on the quote.

Does it ship with the project file or runtime license? No. We ship a test record, not your project. Load your site project and verify the runtime version before the panel goes into service.

Will my MPI cable and connector work? Only if the connector type and pinout match the OEM drawing for this suffix. Send us the cable label photo and we will confirm what we can before shipment.

What do you need to quote the right replacement? Full label photo, project file name, runtime version, MPI address, and panel cutout photos. That five-minute upload prevents most wrong-part returns.